Leave Your Message

66-110kV Oil Immersed Power Transformer - High Efficiency from China Suppliers & Factory

Overview of 110KV Transformer by Tianan Group
Tianan Group proudly presents its advanced 110KV Transformer, a product developed through the integration of cutting-edge technology and extensive industry experience. As a leading China supplier and manufacturer, we have refined the design and production processes to achieve international performance and reliability standards. Our transformers are characterized by low energy losses, low noise levels, minimal partial discharge, and strong resistance to short circuits. With high impedance and a fully sealed construction, we prioritize safety with advanced leakage-proof measures. The unique features of our transformers embody the Tianan quality, making them a preferred choice in the market.

Standards Complied: 
IEC, ANSI, IEEE, GOST, GB, and other international standards.

    Product Features

    Low loss
    Electrical calculation by sophisticated computer programs, combine electrical shielding and magnetic circuit technology.
    The core is made of cold rolled, grain orientation high magnetic silicon steel, to reduce the load loss and no-load current.
    Low partial discharge
    HV lead adopts specially molded insulation parts which effectively ensure the insulation strength and reduces partial discharge.
    High strength
    The tank can withstand the vacuum test and positive pressure test.
    Omni directional location between the core and the tank to guarantee the horizontal position during transportation and operation.
    Low Noise
    The step lapped joints of the core laminations reduce the additional losses arising in the corner portions, reduce the load current and electromagnetic noise.
    Reduce of the flux density and increase the shock absorbing measures at design to reduce the noise.
    Maintenance-free
    Adopts the bell type tank and the international leading technology, ensure 30 years durability, and maintenance-free operation.
    product-description1
    Transformer body assembly

    Date Sheet of Typical Products

    The energy efficiency level of 66 kV oil-immersed three-phase double-winding no-load tap-changing power transformer

    Rated capacity
    kVA

    Level Ⅰ

    Level Ⅱ

    Level Ⅲ

    short circuit impedance
    %

    No-Load Loss
    kW

    Load Loss (75℃)
    kW

    No-Load Loss
    kW

    Load Loss (75℃)
    kW

    No-Load Loss
    kW

    Load Loss (75℃)
    kW

    3150

    2.2

    20.7

    2.6

    20.7

    3.2

    21.9

    8

    4000

    2.6

    24.6

    3.1

    24.6

    3.8

    25.9

    5000

    3.1

    27.6

    3.7

    27.6

    4.6

    29.2

    6300

    4.0

    30.8

    4.7

    30.8

    5.8

    32.5

    9

    8000

    4.9

    36.5

    5.8

    36.5

    7.1

    38.5

    10000

    5.8

    43.0

    6.8

    43.0

    8.4

    45.4

    12500

    6.8

    51.1

    8.1

    51.1

    9.9

    54.0

    16000

    8.3

    62.8

    9.8

    62.8

    12.0

    66.3

    20000

    9.7

    76.1

    11.4

    76.1

    14.1

    80.4

    25000

    11.4

    90.0

    13.5

    90.0

    16.6

    95.0

    31500

    13.5

    108.0

    16.0

    108.0

    19.7

    114.0

    40000

    16.2

    126.9

    19.1

    126.9

    23.5

    134.0

    50000

    19.4

    150.3

    22.9

    150.3

    28.2

    158.7

    63000

    22.9

    178.2

    27.0

    178.2

    33.3

    188.1

    The energy efficiency level of 66 kV oil-immersed three-phase double-winding OLTC power transformer

    Rated capacity
    kVA

    Level Ⅰ

    Level Ⅱ

    Level Ⅲ

    short circuit impedance
    %

    No-Load Loss
    kW

    Load Loss (75℃)
    kW

    No-Load Loss
    kW

    Load Loss (75℃)
    kW

    No-Load Loss
    kW

    Load Loss (75℃)
    kW

    6300

    4.4

    30.8

    5.2

    30.8

    6.4

    32.5

    9

    8000

    5.3

    36.5

    6.2

    36.5

    7.7

    38.5

    10000

    6.2

    43.0

    7.3

    43.0

    9.0

    45.4

    12500

    7.4

    51.1

    8.7

    51.1

    10.7

    54.0

    16000

    8.9

    62.8

    10.5

    62.8

    12.9

    66.3

    20000

    10.6

    76.1

    12.5

    76.1

    15.4

    80.4

    25000

    12.5

    90.0

    14.8

    90.0

    18.2

    95.0

    31500

    14.8

    108.0

    17.5

    108.0

    21.5

    114.0

    40000

    17.7

    126.9

    20.9

    126.9

    25.8

    134.0

    50000

    20.9

    150.3

    24.7

    150.3

    30.4

    158.7

    63000

    24.7

    178.2

    29.2

    178.2

    35.9

    188.1

    The energy efficiency level of 110 kV oil-immersed three-phase double-winding no-load tap-changing power transformer

    Rated capacity
    kVA

    Level Ⅰ

    Level Ⅱ

    Level Ⅲ

    short circuit impedance
    %

    No-Load Loss
    kW

    Load Loss (75℃)
    kW

    No-Load Loss
    kW

    Load Loss (75℃)
    kW

    No-Load Loss
    kW

    Load Loss (75℃)
    kW

    6300

    4.1

    32

    4.8

    32

    5.9

    33

    10.5

    8000

    4.9

    38

    5.8

    38

    7.1

    40

    10000

    5.8

    45

    6.8

    45

    8.4

    48

    12500

    6.8

    53

    8.1

    53

    9.9

    56

    16000

    8.3

    65.7

    9.8

    65.7

    12.0

    69

    20000

    9.7

    79

    11.4

    79

    14.1

    84

    25000

    11.4

    94

    13.5

    94

    16.6

    99

    31500

    13.5

    111

    16.0

    111

    19.7

    117

    40000

    16.2

    133

    19.1

    133

    23.5

    141

    50000

    19.4

    158

    22.9

    158

    28.2

    166

    63000

    22.9

    187

    27.0

    187

    33.3

    198

    75000

    26.0

    212

    30.7

    212

    37.8

    224

    12~14

    90000

    29.9

    245

    35.4

    245

    43.5

    258

    120000

    37.3

    303

    44.1

    303

    54.2

    320

    150000

    44.1

    359

    52.1

    359

    64.1

    379

    180000

    49.5

    411

    58.5

    411

    72.0

    434

    The energy efficiency level of 110 kV oil-immersed three-phase double-winding LV-35kV no-load tap-changing power transformer

    Rated capacity
    kVA

    Level Ⅰ

    Level Ⅱ

    Level Ⅲ

    short circuit impedance
    %

    No-Load Loss
    kW

    Load Loss (75℃)
    kW

    No-Load Loss
    kW

    Load Loss (75℃)
    kW

    No-Load Loss
    kW

    Load Loss (75℃)
    kW

    6300

    4.4

    33

    5.2

    33

    6.4

    35

    10.5

    8000

    5.3

    40

    6.2

    40

    7.7

    42

    10000

    6.2

    47

    7.3

    47

    9.0

    49

    12500

    7.2

    56

    8.5

    56

    10.5

    59

    16000

    8.6

    68

    10.1

    68

    12.5

    72

    20000

    10.2

    85

    12.0

    85

    14.8

    89

    25000

    12.1

    99

    14.2

    99

    17.5

    105

    31500

    14.3

    120

    16.8

    120

    20.7

    126

    40000

    16.9

    140

    20.0

    140

    24.6

    147

    50000

    20.3

    174

    24.0

    174

    29.5

    183

    63000

    24.0

    209

    28.3

    209

    34.9

    220

    6300

    4.4

    33

    5.2

    33

    6.4

    35

    8000

    5.3

    40

    6.2

    40

    7.7

    42

    10000

    6.2

    47

    7.3

    47

    9.0

    49

    The energy efficiency level of 110 kV oil-immersed three-phase three-winding no-load tap-changing power transformer

    Rated capacity
    kVA

    Level Ⅰ

    Level Ⅱ

    Level Ⅲ

    short circuit impedance
    %

    No-Load Loss
    kW

    Load Loss (75℃)
    kW

    No-Load Loss
    kW

    Load Loss (75℃)
    kW

    No-Load Loss
    kW

    Load Loss (75℃)
    kW

    Set up voltage

    Set down voltage

    6300

    4.9

    40

    5.8

    40

    7.1

    42

    H-M:17.5~18.5

    H-L:10.5

    M-L:6.5

    H-M:10.5

    H-L:17.5~18.5

    M-L:6.5

    8000

    5.8

    48

    6.9

    48

    8.5

    50

    10000

    6.9

    56

    8.2

    56

    10.1

    59

    12500

    8.1

    67

    9.6

    67

    11.8

    70

    16000

    9.8

    81

    11.6

    81

    14.3

    86

    20000

    11.6

    95

    13.7

    95

    16.9

    101

    25000

    13.5

    113

    16.0

    113

    19.7

    120

    31500

    16.2

    134

    19.1

    134

    23.5

    142

    H-M:17.5~18.5

    H-L:10.5

    M-L:6.5

    H-M:10.5

    H-L:17.5~18.5

    M-L:6.5

    40000

    19.1

    161

    22.6

    161

    27.8

    170

    50000

    22.9

    192

    27.0

    192

    33.3

    202

    63000

    27.1

    230

    32.0

    230

    39.4

    243

    6300

    4.9

    40

    5.8

    40

    7.1

    42

    The energy efficiency level of 110 kV oil-immersed three-phase double-winding OLTC power transformer

    Rated capacity
    kVA

    Level Ⅰ

    Level Ⅱ

    Level Ⅲ

    short circuit impedance
    %

    No-Load Loss
    kW

    Load Loss (75℃)
    kW

    No-Load Loss
    kW

    Load Loss (75℃)
    kW

    No-Load Loss
    kW

    Load Loss (75℃)
    kW

    6300

    4.4

    32

    5.2

    32

    6.4

    33

    10.5

    8000

    5.3

    38

    6.2

    38

    7.7

    40

    10000

    6.2

    45

    7.3

    45

    9.0

    48

    12500

    7.4

    53

    8.7

    53

    10.7

    56

    16000

    8.9

    66

    10.5

    66

    12.9

    69

    20000

    10.6

    79

    12.5

    79

    15.4

    84

    25000

    12.5

    94

    14.8

    94

    18.2

    99

    31500

    14.9

    111

    17.6

    111

    21.6

    117

    40000

    17.8

    140

    21.0

    140

    25.8

    148

    50000

    21.0

    175

    24.8

    175

    30.6

    184

    63000

    25.0

    209

    29.5

    209

    36.3

    220

    The energy efficiency level of 110 kV oil-immersed three-phase three-winding OLTC power transformer

    Rated capacity
    kVA

    Level Ⅰ

    Level Ⅱ

    Level Ⅲ

    short circuit impedance
    %

    No-Load Loss
    kW

    Load Loss (75℃)
    kW

    No-Load Loss
    kW

    Load Loss (75℃)
    kW

    No-Load Loss
    kW

    Load Loss (75℃)
    kW

    6300

    5.3

    40

    6.2

    40

    7.7

    42

    H-M:10.5

    H-L:17.5~18.5

    M-L:6.5

    8000

    6.3

    48

    7.5

    48

    9.2

    50

    10000

    7.5

    56

    8.8

    56

    10.9

    59

    12500

    8.9

    67

    10.5

    67

    12.9

    70

    16000

    10.6

    81

    12.5

    81

    15.4

    86

    20000

    12.5

    95

    14.8

    95

    18.2

    101

    25000

    14.9

    113

    17.6

    113

    21.6

    120

    31500

    17.7

    134

    20.9

    134

    25.7

    142

    40000

    21.2

    161

    25.0

    161

    30.8

    170

    50000

    25.0

    192

    29.6

    192

    36.4

    202

    63000

    29.8

    230

    35.2

    230

    43.3

    243

    Frequently Asked Questions

    Q1: How do these transformers achieve low loss and low no-load current?

    A1: The core is manufactured using cold-rolled, grain-oriented high magnetic silicon steel. Additionally, sophisticated computer programs are used to calculate and combine electrical shielding with magnetic circuit technology to minimize load loss and no-load current.

    Q2: What design features contribute to the low noise level of these power transformers?

    A2: The core laminations utilize step-lapped joints to reduce additional losses in corner portions, decreasing load current and electromagnetic noise. We also reduce flux density and apply shock-absorbing measures at the design stage to further minimize noise.

    Q3: How is the risk of partial discharge managed in high voltage operations?

    A3: The High Voltage (HV) lead is designed with specially molded insulation parts. These parts effectively secure insulation strength and significantly reduce partial discharge during operation.

    Q4: Are these oil-immersed transformers structurally reinforced for transport and installation?

    A4: Yes, the tank is designed to withstand both vacuum and positive pressure tests. An omni-directional location system between the core and the tank guarantees that the horizontal position is securely maintained during transportation and field operations.

    Q5: What makes these transformers maintenance-free?

    A5: By incorporating a bell-type tank and international leading manufacturing technologies, these transformers are built for a durability of 30 years, ensuring long-term, maintenance-free operation.

    Q6: What is the difference between Level I, Level II, and Level III energy efficiency levels?

    A6: These levels correspond to standard energy efficiency grades. Level I represents the highest efficiency with the lowest no-load and load losses, while Level II and Level III have higher loss parameters as detailed in our typical product data sheets.

    Leave Your Message