Leave Your Message

66-110kV Oil Immersed Power Transformer - High Performance from China Suppliers & Factory

General
The 110KV Transformer manufactured by Tianan Group exemplifies cutting-edge design and technology, derived from extensive research and innovative applications of advanced techniques. As a prominent China supplier, we integrate our vast experience in transformer production and design to ensure our products meet international performance and reliability standards. Our commitment to continuous improvement has led us to develop a series of transformers that embody the unique characteristics of Tianan, including low losses, low noise, minimal partial discharge, robust anti-short-circuit capability, high impedance, and a fully sealed structure. Additionally, we implement specialized measures for leakage protection, making our transformers a reliable choice for various applications. The features of our transformers can be summarized as follows:

,

Standards: 
IEC, ANSI, IEEE, GOST, GB, and more, reflecting our dedication to quality as a leading factory in the industry.

    Product Features

    Low loss
    • Electrical calculation by sophisticated computer programs, combine electrical shielding and magnetic circuit technology.
    • The core is made of cold rolled, grain orientation high magnetic silicon steel, to reduce the load loss and no-load current.
    Low partial discharge
    • HV lead adopts specially molded insulation parts which effectively ensure the insulation strength and reduces partial discharge.
    High strength
    • The tank can withstand the vacuum test and positive pressure test.
    • Omni directional location between the core and the tank to guarantee the horizontal position during transportation and operation.
    Low Noise
    • The step lapped joints of the core laminations reduce the additional losses arising in the corner portions, reduce the load current and electromagnetic noise.
    • Reduce of the flux density and increase the shock absorbing measures at design to reduce the noise.
    Maintenance-free
    • Adopts the bell type tank and the international leading technology, ensure 30 years durability,and maintenance-free operation.

    Data Sheet of Typical Products

    The energy efficiency level of 66 kV oil-immersed three-phase double-winding no-load tap-changing power transformer

    Rated capacity
    kVA

    Level Ⅰ

    Level Ⅱ

    Level Ⅲ

    short circuit impedance
    %

    No-Load Loss
    kW

    Load Loss (75℃)
    kW

    No-Load Loss
    kW

    Load Loss (75℃)
    kW

    No-Load Loss
    kW

    Load Loss (75℃)
    kW

    3150

    2.2

    20.7

    2.6

    20.7

    3.2

    21.9

    8

    4000

    2.6

    24.6

    3.1

    24.6

    3.8

    25.9

    5000

    3.1

    27.6

    3.7

    27.6

    4.6

    29.2

    6300

    4.0

    30.8

    4.7

    30.8

    5.8

    32.5

    9

    8000

    4.9

    36.5

    5.8

    36.5

    7.1

    38.5

    10000

    5.8

    43.0

    6.8

    43.0

    8.4

    45.4

    12500

    6.8

    51.1

    8.1

    51.1

    9.9

    54.0

    16000

    8.3

    62.8

    9.8

    62.8

    12.0

    66.3

    20000

    9.7

    76.1

    11.4

    76.1

    14.1

    80.4

    25000

    11.4

    90.0

    13.5

    90.0

    16.6

    95.0

    31500

    13.5

    108.0

    16.0

    108.0

    19.7

    114.0

    40000

    16.2

    126.9

    19.1

    126.9

    23.5

    134.0

    50000

    19.4

    150.3

    22.9

    150.3

    28.2

    158.7

    63000

    22.9

    178.2

    27.0

    178.2

    33.3

    188.1

    The energy efficiency level of 66 kV oil-immersed three-phase double-winding OLTC power transformer

    Rated capacity
    kVA

    Level Ⅰ

    Level Ⅱ

    Level Ⅲ

    short circuit impedance
    %

    No-Load Loss
    kW

    Load Loss (75℃)
    kW

    No-Load Loss
    kW

    Load Loss (75℃)
    kW

    No-Load Loss
    kW

    Load Loss (75℃)
    kW

    6300

    4.4

    30.8

    5.2

    30.8

    6.4

    32.5

    9

    8000

    5.3

    36.5

    6.2

    36.5

    7.7

    38.5

    10000

    6.2

    43.0

    7.3

    43.0

    9.0

    45.4

    12500

    7.4

    51.1

    8.7

    51.1

    10.7

    54.0

    16000

    8.9

    62.8

    10.5

    62.8

    12.9

    66.3

    20000

    10.6

    76.1

    12.5

    76.1

    15.4

    80.4

    25000

    12.5

    90.0

    14.8

    90.0

    18.2

    95.0

    31500

    14.8

    108.0

    17.5

    108.0

    21.5

    114.0

    40000

    17.7

    126.9

    20.9

    126.9

    25.8

    134.0

    50000

    20.9

    150.3

    24.7

    150.3

    30.4

    158.7

    63000

    24.7

    178.2

    29.2

    178.2

    35.9

    188.1

    The energy efficiency level of 110 kV oil-immersed three-phase double-winding no-load tap-changing power transformer

    Rated capacity
    kVA

    Level Ⅰ

    Level Ⅱ

    Level Ⅲ

    short circuit impedance
    %

    No-Load Loss
    kW

    Load Loss (75℃)
    kW

    No-Load Loss
    kW

    Load Loss (75℃)
    kW

    No-Load Loss
    kW

    Load Loss (75℃)
    kW

    6300

    4.1

    32

    4.8

    32

    5.9

    33

    10.5

    8000

    4.9

    38

    5.8

    38

    7.1

    40

    10000

    5.8

    45

    6.8

    45

    8.4

    48

    12500

    6.8

    53

    8.1

    53

    9.9

    56

    16000

    8.3

    65.7

    9.8

    65.7

    12.0

    69

    20000

    9.7

    79

    11.4

    79

    14.1

    84

    25000

    11.4

    94

    13.5

    94

    16.6

    99

    31500

    13.5

    111

    16.0

    111

    19.7

    117

    40000

    16.2

    133

    19.1

    133

    23.5

    141

    50000

    19.4

    158

    22.9

    158

    28.2

    166

    63000

    22.9

    187

    27.0

    187

    33.3

    198

    75000

    26.0

    212

    30.7

    212

    37.8

    224

    12~14

    90000

    29.9

    245

    35.4

    245

    43.5

    258

    120000

    37.3

    303

    44.1

    303

    54.2

    320

    150000

    44.1

    359

    52.1

    359

    64.1

    379

    180000

    49.5

    411

    58.5

    411

    72.0

    434

    The energy efficiency level of 110 kV oil-immersed three-phase double-winding LV-35kV no-load tap-changing power transformer

    Rated capacity
    kVA

    Level Ⅰ

    Level Ⅱ

    Level Ⅲ

    short circuit impedance
    %

    No-Load Loss
    kW

    Load Loss (75℃)
    kW

    No-Load Loss
    kW

    Load Loss (75℃)
    kW

    No-Load Loss
    kW

    Load Loss (75℃)
    kW

    6300

    4.4

    33

    5.2

    33

    6.4

    35

    10.5

    8000

    5.3

    40

    6.2

    40

    7.7

    42

    10000

    6.2

    47

    7.3

    47

    9.0

    49

    12500

    7.2

    56

    8.5

    56

    10.5

    59

    16000

    8.6

    68

    10.1

    68

    12.5

    72

    20000

    10.2

    85

    12.0

    85

    14.8

    89

    25000

    12.1

    99

    14.2

    99

    17.5

    105

    31500

    14.3

    120

    16.8

    120

    20.7

    126

    40000

    16.9

    140

    20.0

    140

    24.6

    147

    50000

    20.3

    174

    24.0

    174

    29.5

    183

    63000

    24.0

    209

    28.3

    209

    34.9

    220

    6300

    4.4

    33

    5.2

    33

    6.4

    35

    8000

    5.3

    40

    6.2

    40

    7.7

    42

    10000

    6.2

    47

    7.3

    47

    9.0

    49

    The energy efficiency level of 110 kV oil-immersed three-phase three-winding no-load tap-changing power transformer

    Rated capacity
    kVA

    Level Ⅰ

    Level Ⅱ

    Level Ⅲ

    short circuit impedance
    %

    No-Load Loss
    kW

    Load Loss (75℃)
    kW

    No-Load Loss
    kW

    Load Loss (75℃)
    kW

    No-Load Loss
    kW

    Load Loss (75℃)
    kW

    Set up voltage

    Set down voltage

    6300

    4.9

    40

    5.8

    40

    7.1

    42

    H-M:17.5~18.5

    H-L:10.5

    M-L:6.5

    H-M:10.5

    H-L:17.5~18.5

    M-L:6.5

    8000

    5.8

    48

    6.9

    48

    8.5

    50

    10000

    6.9

    56

    8.2

    56

    10.1

    59

    12500

    8.1

    67

    9.6

    67

    11.8

    70

    16000

    9.8

    81

    11.6

    81

    14.3

    86

    20000

    11.6

    95

    13.7

    95

    16.9

    101

    25000

    13.5

    113

    16.0

    113

    19.7

    120

    31500

    16.2

    134

    19.1

    134

    23.5

    142

    H-M:17.5~18.5

    H-L:10.5

    M-L:6.5

    H-M:10.5

    H-L:17.5~18.5

    M-L:6.5

    40000

    19.1

    161

    22.6

    161

    27.8

    170

    50000

    22.9

    192

    27.0

    192

    33.3

    202

    63000

    27.1

    230

    32.0

    230

    39.4

    243

    6300

    4.9

    40

    5.8

    40

    7.1

    42

    The energy efficiency level of 110 kV oil-immersed three-phase double-winding OLTC power transformer

    Rated capacity
    kVA

    Level Ⅰ

    Level Ⅱ

    Level Ⅲ

    short circuit impedance
    %

    No-Load Loss
    kW

    Load Loss (75℃)
    kW

    No-Load Loss
    kW

    Load Loss (75℃)
    kW

    No-Load Loss
    kW

    Load Loss (75℃)
    kW

    6300

    4.4

    32

    5.2

    32

    6.4

    33

    10.5

    8000

    5.3

    38

    6.2

    38

    7.7

    40

    10000

    6.2

    45

    7.3

    45

    9.0

    48

    12500

    7.4

    53

    8.7

    53

    10.7

    56

    16000

    8.9

    66

    10.5

    66

    12.9

    69

    20000

    10.6

    79

    12.5

    79

    15.4

    84

    25000

    12.5

    94

    14.8

    94

    18.2

    99

    31500

    14.9

    111

    17.6

    111

    21.6

    117

    40000

    17.8

    140

    21.0

    140

    25.8

    148

    50000

    21.0

    175

    24.8

    175

    30.6

    184

    63000

    25.0

    209

    29.5

    209

    36.3

    220

    The energy efficiency level of 110 kV oil-immersed three-phase three-winding OLTC power transformer

    Rated capacity
    kVA

    Level Ⅰ

    Level Ⅱ

    Level Ⅲ

    short circuit impedance
    %

    No-Load Loss
    kW

    Load Loss (75℃)
    kW

    No-Load Loss
    kW

    Load Loss (75℃)
    kW

    No-Load Loss
    kW

    Load Loss (75℃)
    kW

    6300

    5.3

    40

    6.2

    40

    7.7

    42

    H-M:10.5

    H-L:17.5~18.5

    M-L:6.5

    8000

    6.3

    48

    7.5

    48

    9.2

    50

    10000

    7.5

    56

    8.8

    56

    10.9

    59

    12500

    8.9

    67

    10.5

    67

    12.9

    70

    16000

    10.6

    81

    12.5

    81

    15.4

    86

    20000

    12.5

    95

    14.8

    95

    18.2

    101

    25000

    14.9

    113

    17.6

    113

    21.6

    120

    31500

    17.7

    134

    20.9

    134

    25.7

    142

    40000

    21.2

    161

    25.0

    161

    30.8

    170

    50000

    25.0

    192

    29.6

    192

    36.4

    202

    63000

    29.8

    230

    35.2

    230

    43.3

    243

    Frequently Asked Questions

    How do these transformers achieve low electrical losses?
    We utilize sophisticated computer programs for electrical calculations, combining advanced electrical shielding and magnetic circuit technology. Furthermore, the core is constructed from cold-rolled, grain-oriented high magnetic silicon steel to minimize load loss and no-load current.
    What design measures are taken to reduce partial discharge in the HV leads?
    The High Voltage (HV) lead is equipped with specially molded insulation parts. This design effectively guarantees insulation strength and significantly lowers partial discharge.
    How is the physical strength of the transformer tank guaranteed?
    The transformer tank is designed to withstand both vacuum and positive pressure tests. Additionally, omni-directional location structures between the core and the tank secure the horizontal position during transit and operation.
    What features help reduce the electromagnetic and load noise of the system?
    We use step-lapped joints in the core laminations to reduce corner losses, load current, and electromagnetic noise. We also decrease flux density and implement shock-absorbing measures at the design phase.
    What makes these transformers maintenance-free?
    By employing a bell-type tank structure and leading international sealing and manufacturing technologies, these power transformers ensure a durability of up to 30 years with maintenance-free operation.
    What energy efficiency levels do these typical products support?
    Our typical 66 kV and 110 kV oil-immersed three-phase power transformers are designed and graded across Level I, Level II, and Level III energy efficiency standards.

    Leave Your Message