66-110kV Oil Immersed Power Transformers from China Factory - Reliable Suppliers for Low Loss, Low Noise Solutions
Product Features
- Electrical calculation by sophisticated computer programs, combine electrical shielding and magnetic circuit technology.
- The core is made of cold rolled, grain orientation high magnetic silicon steel, to reduce the load loss and no-load current.
- HV lead adopts specially molded insulation parts which effectively ensure the insulation strength and reduces partial discharge.
- The tank can withstand the vacuum test and positive pressure test.
- Omni directional location between the core and the tank to guarantee the horizontal position during transportation and operation.
- The step lapped joints of the core laminations reduce the additional losses arising in the corner portions, reduce the load current and electromagnetic noise.
- Reduce of the flux density and increase the shock absorbing measures at design to reduce the noise.
- Adopts the bell type tank and the international leading technology, ensure 30 years durability, and maintenance-free operation.

Data Sheet of Typical Products
| Rated capacity kVA |
Level Ⅰ | Level Ⅱ | Level Ⅲ | short circuit impedance % |
|||
| No-Load Loss kW |
Load Loss (75℃) kW |
No-Load Loss kW |
Load Loss (75℃) kW |
No-Load Loss kW |
Load Loss (75℃) kW |
||
| 3150 | 2.2 | 20.7 | 2.6 | 20.7 | 3.2 | 21.9 | 8 |
| 4000 | 2.6 | 24.6 | 3.1 | 24.6 | 3.8 | 25.9 | |
| 5000 | 3.1 | 27.6 | 3.7 | 27.6 | 4.6 | 29.2 | |
| 6300 | 4.0 | 30.8 | 4.7 | 30.8 | 5.8 | 32.5 | 9 |
| 8000 | 4.9 | 36.5 | 5.8 | 36.5 | 7.1 | 38.5 | |
| 10000 | 5.8 | 43.0 | 6.8 | 43.0 | 8.4 | 45.4 | |
| 12500 | 6.8 | 51.1 | 8.1 | 51.1 | 9.9 | 54.0 | |
| 16000 | 8.3 | 62.8 | 9.8 | 62.8 | 12.0 | 66.3 | |
| 20000 | 9.7 | 76.1 | 11.4 | 76.1 | 14.1 | 80.4 | |
| 25000 | 11.4 | 90.0 | 13.5 | 90.0 | 16.6 | 95.0 | |
| 31500 | 13.5 | 108.0 | 16.0 | 108.0 | 19.7 | 114.0 | |
| 40000 | 16.2 | 126.9 | 19.1 | 126.9 | 23.5 | 134.0 | |
| 50000 | 19.4 | 150.3 | 22.9 | 150.3 | 28.2 | 158.7 | |
| 63000 | 22.9 | 178.2 | 27.0 | 178.2 | 33.3 | 188.1 | |
| Rated capacity kVA |
Level Ⅰ | Level Ⅱ | Level Ⅲ | short circuit impedance % |
|||
| No-Load Loss kW |
Load Loss (75℃) kW |
No-Load Loss kW |
Load Loss (75℃) kW |
No-Load Loss kW |
Load Loss (75℃) kW |
||
| 6300 | 4.4 | 30.8 | 5.2 | 30.8 | 6.4 | 32.5 | 9 |
| 8000 | 5.3 | 36.5 | 6.2 | 36.5 | 7.7 | 38.5 | |
| 10000 | 6.2 | 43.0 | 7.3 | 43.0 | 9.0 | 45.4 | |
| 12500 | 7.4 | 51.1 | 8.7 | 51.1 | 10.7 | 54.0 | |
| 16000 | 8.9 | 62.8 | 10.5 | 62.8 | 12.9 | 66.3 | |
| 20000 | 10.6 | 76.1 | 12.5 | 76.1 | 15.4 | 80.4 | |
| 25000 | 12.5 | 90.0 | 14.8 | 90.0 | 18.2 | 95.0 | |
| 31500 | 14.8 | 108.0 | 17.5 | 108.0 | 21.5 | 114.0 | |
| 40000 | 17.7 | 126.9 | 20.9 | 126.9 | 25.8 | 134.0 | |
| 50000 | 20.9 | 150.3 | 24.7 | 150.3 | 30.4 | 158.7 | |
| 63000 | 24.7 | 178.2 | 29.2 | 178.2 | 35.9 | 188.1 | |
| Rated capacity kVA |
Level Ⅰ | Level Ⅱ | Level Ⅲ | short circuit impedance % |
|||
| No-Load Loss kW |
Load Loss (75℃) kW |
No-Load Loss kW |
Load Loss (75℃) kW |
No-Load Loss kW |
Load Loss (75℃) kW |
||
| 6300 | 4.1 | 32 | 4.8 | 32 | 5.9 | 33 | 10.5 |
| 8000 | 4.9 | 38 | 5.8 | 38 | 7.1 | 40 | |
| 10000 | 5.8 | 45 | 6.8 | 45 | 8.4 | 48 | |
| 12500 | 6.8 | 53 | 8.1 | 53 | 9.9 | 56 | |
| 16000 | 8.3 | 65.7 | 9.8 | 65.7 | 12.0 | 69 | |
| 20000 | 9.7 | 79 | 11.4 | 79 | 14.1 | 84 | |
| 25000 | 11.4 | 94 | 13.5 | 94 | 16.6 | 99 | |
| 31500 | 13.5 | 111 | 16.0 | 111 | 19.7 | 117 | |
| 40000 | 16.2 | 133 | 19.1 | 133 | 23.5 | 141 | |
| 50000 | 19.4 | 158 | 22.9 | 158 | 28.2 | 166 | |
| 63000 | 22.9 | 187 | 27.0 | 187 | 33.3 | 198 | |
| 75000 | 26.0 | 212 | 30.7 | 212 | 37.8 | 224 | 12~14 |
| 90000 | 29.9 | 245 | 35.4 | 245 | 43.5 | 258 | |
| 120000 | 37.3 | 303 | 44.1 | 303 | 54.2 | 320 | |
| 150000 | 44.1 | 359 | 52.1 | 359 | 64.1 | 379 | |
| 180000 | 49.5 | 411 | 58.5 | 411 | 72.0 | 434 | |
| Rated capacity kVA |
Level Ⅰ | Level Ⅱ | Level Ⅲ | short circuit impedance % |
|||
| No-Load Loss kW |
Load Loss (75℃) kW |
No-Load Loss kW |
Load Loss (75℃) kW |
No-Load Loss kW |
Load Loss (75℃) kW |
||
| 6300 | 4.4 | 33 | 5.2 | 33 | 6.4 | 35 | 10.5 |
| 8000 | 5.3 | 40 | 6.2 | 40 | 7.7 | 42 | |
| 10000 | 6.2 | 47 | 7.3 | 47 | 9.0 | 49 | |
| 12500 | 7.2 | 56 | 8.5 | 56 | 10.5 | 59 | |
| 16000 | 8.6 | 68 | 10.1 | 68 | 12.5 | 72 | |
| 20000 | 10.2 | 85 | 12.0 | 85 | 14.8 | 89 | |
| 25000 | 12.1 | 99 | 14.2 | 99 | 17.5 | 105 | |
| 31500 | 14.3 | 120 | 16.8 | 120 | 20.7 | 126 | |
| 40000 | 16.9 | 140 | 20.0 | 140 | 24.6 | 147 | |
| 50000 | 20.3 | 174 | 24.0 | 174 | 29.5 | 183 | |
| 63000 | 24.0 | 209 | 28.3 | 209 | 34.9 | 220 | |
| 6300 | 4.4 | 33 | 5.2 | 33 | 6.4 | 35 | |
| 8000 | 5.3 | 40 | 6.2 | 40 | 7.7 | 42 | |
| 10000 | 6.2 | 47 | 7.3 | 47 | 9.0 | 49 | |
| Rated capacity kVA |
Level Ⅰ | Level Ⅱ | Level Ⅲ | short circuit impedance % |
||||
| No-Load Loss kW |
Load Loss (75℃) kW |
No-Load Loss kW |
Load Loss (75℃) kW |
No-Load Loss kW |
Load Loss (75℃) kW |
Set up voltage | Set down voltage | |
| 6300 | 4.9 | 40 | 5.8 | 40 | 7.1 | 42 | H-M:17.5~18.5 H-L:10.5 M-L:6.5 |
H-M:10.5 H-L:17.5~18.5 M-L:6.5 |
| 8000 | 5.8 | 48 | 6.9 | 48 | 8.5 | 50 | ||
| 10000 | 6.9 | 56 | 8.2 | 56 | 10.1 | 59 | ||
| 12500 | 8.1 | 67 | 9.6 | 67 | 11.8 | 70 | ||
| 16000 | 9.8 | 81 | 11.6 | 81 | 14.3 | 86 | ||
| 20000 | 11.6 | 95 | 13.7 | 95 | 16.9 | 101 | ||
| 25000 | 13.5 | 113 | 16.0 | 113 | 19.7 | 120 | ||
| 31500 | 16.2 | 134 | 19.1 | 134 | 23.5 | 142 | H-M:17.5~18.5 H-L:10.5 M-L:6.5 |
H-M:10.5 H-L:17.5~18.5 M-L:6.5 |
| 40000 | 19.1 | 161 | 22.6 | 161 | 27.8 | 170 | ||
| 50000 | 22.9 | 192 | 27.0 | 192 | 33.3 | 202 | ||
| 63000 | 27.1 | 230 | 32.0 | 230 | 39.4 | 243 | ||
| 6300 | 4.9 | 40 | 5.8 | 40 | 7.1 | 42 | ||
| Rated capacity kVA |
Level Ⅰ | Level Ⅱ | Level Ⅲ | short circuit impedance % |
|||
| No-Load Loss kW |
Load Loss (75℃) kW |
No-Load Loss kW |
Load Loss (75℃) kW |
No-Load Loss kW |
Load Loss (75℃) kW |
||
| 6300 | 4.4 | 32 | 5.2 | 32 | 6.4 | 33 | 10.5 |
| 8000 | 5.3 | 38 | 6.2 | 38 | 7.7 | 40 | |
| 10000 | 6.2 | 45 | 7.3 | 45 | 9.0 | 48 | |
| 12500 | 7.4 | 53 | 8.7 | 53 | 10.7 | 56 | |
| 16000 | 8.9 | 66 | 10.5 | 66 | 12.9 | 69 | |
| 20000 | 10.6 | 79 | 12.5 | 79 | 15.4 | 84 | |
| 25000 | 12.5 | 94 | 14.8 | 94 | 18.2 | 99 | |
| 31500 | 14.9 | 111 | 17.6 | 111 | 21.6 | 117 | |
| 40000 | 17.8 | 140 | 21.0 | 140 | 25.8 | 148 | |
| 50000 | 21.0 | 175 | 24.8 | 175 | 30.6 | 184 | |
| 63000 | 25.0 | 209 | 29.5 | 209 | 36.3 | 220 | |
| Rated capacity kVA |
Level Ⅰ | Level Ⅱ | Level Ⅲ | short circuit impedance % |
|||
| No-Load Loss kW |
Load Loss (75℃) kW |
No-Load Loss kW |
Load Loss (75℃) kW |
No-Load Loss kW |
Load Loss (75℃) kW |
||
| 6300 | 5.3 | 40 | 6.2 | 40 | 7.7 | 42 | H-M:10.5 H-L:17.5~18.5 M-L:6.5 |
| 8000 | 6.3 | 48 | 7.5 | 48 | 9.2 | 50 | |
| 10000 | 7.5 | 56 | 8.8 | 56 | 10.9 | 59 | |
| 12500 | 8.9 | 67 | 10.5 | 67 | 12.9 | 70 | |
| 16000 | 10.6 | 81 | 12.5 | 81 | 15.4 | 86 | |
| 20000 | 12.5 | 95 | 14.8 | 95 | 18.2 | 101 | |
| 25000 | 14.9 | 113 | 17.6 | 113 | 21.6 | 120 | |
| 31500 | 17.7 | 134 | 20.9 | 134 | 25.7 | 142 | |
| 40000 | 21.2 | 161 | 25.0 | 161 | 30.8 | 170 | |
| 50000 | 25.0 | 192 | 29.6 | 192 | 36.4 | 202 | |
| 63000 | 29.8 | 230 | 35.2 | 230 | 43.3 | 243 | |
Frequently Asked Questions
Low loss is achieved through sophisticated computer program calculations that combine electrical shielding and magnetic circuit technology. Additionally, the core is made of cold-rolled, grain-oriented high magnetic silicon steel to reduce load loss and no-load current.
The high voltage (HV) lead adopts specially molded insulation parts, which effectively ensure high insulation strength and minimize partial discharge during operation.
Yes, the transformer tank is designed to withstand both vacuum tests and positive pressure tests. An omni-directional location system between the core and the tank also guarantees the horizontal position is maintained during transportation and operation.
Noise is minimized by using step-lapped joints in the core laminations to reduce corner losses and load current. Additionally, we reduce the flux density and incorporate shock-absorbing measures into the design to further lower electromagnetic noise.
Yes. By utilizing a bell-type tank and international leading manufacturing technologies, these power transformers ensure up to 30 years of durability and maintenance-free operation.
The provided data sheets cover typical performance and energy efficiency levels for 66 kV and 110 kV oil-immersed three-phase double-winding and three-winding power transformers, including both no-load tap-changing and OLTC models.