General 
The KYN61-40.5 withdrawable metal-clad switchgear, produced by leading China suppliers, is an efficient and reliable solution for high-voltage applications. This switchgear operates at 40.5kV and features a three-phase AC system using a single busbar and single sectional configuration.

,

 

,

Designed for extensive power distribution needs, the KYN61 switchgear is ideally suited for substations involved in transmission and transformation, as well as sectors such as wind farms, iron and steel production, petroleum and chemical industries, mining operations, and the paper and food sectors. It provides essential control, protection, and monitoring functions. Our factory ensures that each unit meets high-quality standards, making it a valuable asset for your electrical infrastructure.

    Detail Introduction

    In the KYN61-40.5 withdrawable AC metal-clad switchgear, the handcart is equipped with an integrated ZN85 (VTD9) ND4-40.5 vacuum circuit breaker or a corresponding SF6 circuit breaker as the main switch. The design is compact, with superior performance and high reliability.
    KYN61 switchgear comply with the standards: IEC62271-200, GB3906 as well as many other national specifications, with reliable "five-protection interlock" function, providing a safer environment for the operators, with high structure strength, safe and user-friendly, reduced installation and maintenance costs, can completely satisfy user requirements.

    Service Conditions

    Ambient temperature:
    -15℃ ~ +40℃
    Altitude:
    ≤1000M
    Relative humidity:
    Daily average ≤95%
    Monthly average ≤90%
    Seismic resistant level:
    < Grade 8
    Ambient air:
    Free of corrosive or flammable gases, vapor, etc.
    Note: If the service environment exceeds the above conditions, please confirm with the manufacturer.

    Technical Data

    Main technical data of KYN61 switchgear
    Item Unit Technical parameters
    Rated voltage kV 40.5
    Rated frequency Hz 50/60
    Rated current of branch busbar A 630、1250、1600、2000、2500、3150
    Rated insulation level Power frequency withstand voltage (1 min) kV 95/118 (isolating fracture)
    Lightning impulse withstand voltage 185/215 (isolating fracture)
    Power frequency withstand voltage of auxiliary circuit (1 min) V 2000
    Rated short circuit breaking current (rms) kA 25、31.5
    Rated short time making current (peak) kA 63、80
    Rated short time peak withstand current kA 63、80
    Rated short time withstand current (4s) kA 25、31.5
    Rated voltage of auxiliary control circuit V DC110/220 AC220
    Protection degree - External enclosure: IP4X (the panel open: IP2X)
    External dimensions of switchgear (W x D x H) mm 1400×2800×2600    1200×2600×2400 (optional)

    Structure Features

    KYN61 switchgear is designed as per the standard of metal-clad switchgear, conforms to IEC 62271 and GB/T3906. It mainly includes panel structure and the withdrawable part. The panel itself consists of four independent compartments: busbar compartment, circuit breaker compartment, cable compartment, low voltage compartment. The protection degree of enclosure is IP4X, and IP2X for compartments. The withdrawable part includes the main switch (or other functional components) and support part. (The structure is shown in drawing 1)
    KYN61 switchgear provides bottom and overhead incoming and outgoing cable types, typical scheme including incomer, feeder, metering, measuring coupler, etc.
    Main Compartments
    A. Instrument room
    B. Circuit breaker room
    C. Busbar room
    D. Cable room
    Structure Components
    1. Panel
    2. Circuit breaker
    3. Contact box
    4. Secondary plug device
    5. Valve
    6. Pressure relief device
    7. Small busbar
    8. Busbar bushing
    9. Main busbar
    10. Branch busbar
    11. Fixed contact
    12. Insulated clapboard
    13. Earthing switch
    14. Current transformer
    15. Cable
    16. Cable cover plate
    17. Earthing busbar

    Order Notes

    The clients should provide the following documents:
    • Main wiring scheme No., single line system diagram, arrangement diagram and layout plan.
    • The requirements for control, measurement and protection of switchgears, and requirements for other interlocks and automatic devices.
    • Main components type, specification and quantity in switchgear.
    • If need busbar bridge, please provide the size of span and height.
    • If the switchgear used under special condition, please inform the details.
    • Please provide type and quantity if need additional parts.

    Frequently Asked Questions

    What standard components are equipped in the KYN61-40.5 switchgear handcart?
    The handcart is equipped with an integrated ZN85 (VTD9) ND4-40.5 vacuum circuit breaker or a corresponding SF6 circuit breaker as the main switch, designed for compact, high-performance, and reliable operation.
    What standards does the KYN61 switchgear comply with?
    It complies with international standards such as IEC62271-200 and GB3906, along with various other national specifications, ensuring high structure strength and standard safety compliance.
    What are the normal ambient temperature and altitude limits for operation?
    The standard operating ambient temperature ranges from -15℃ to +40℃, and the installation altitude should be less than or equal to 1000 meters. For conditions exceeding these limits, please contact the manufacturer.
    What is the protection degree of the switchgear enclosure and its compartments?
    The external enclosure has a protection degree of IP4X (IP2X when the panel is open), while the internal compartments feature a protection degree of IP2X.
    What are the four main compartments inside the KYN61 switchgear panel?
    The panel structure consists of four independent compartments: the busbar compartment, the circuit breaker compartment, the cable compartment, and the low voltage compartment.
    What documents should be provided when placing an order?
    Clients need to provide the main wiring scheme, control/measurement/protection requirements, main components specifications, busbar bridge dimensions (if applicable), special environmental details, and types/quantities of any additional parts required.