0102030405
China Metal-Oxide Surge Arrester Factory - Top Suppliers for Over-Voltage Protection Solutions
General
Polymer-housed metal-oxide surge arrester is the scientific achievement that combines the advantages of organic insulation material and traditional porcelain-clad MOA technique. It has excellent insulation performance, high dialectical strength, anti-leaking, anti-electric corrosion, heat-resisting, cold-resisting, anti-aging, explosion-proof, and good chemical stability, hydrophobic property, and nice sealing. It is designed and manufactured strictly following the standard of IEC and GB, and achieves advantage against the competitive international products.
Normal Service conditions
- For indoors and outdoors;
- Ambient air temperature within the range of -40℃~+40℃;
- Altitude not exceeding 2600m;
- Frequency for A.C. power supply not less than 48Hz and not exceeding 62Hz;
- Power Frequency voltage applied continuously between the terminals of the arrester not exceeding its continuous operating voltage;
- Earthquake intensity: 8 degree and below;
- Maximal wind velocity not exceeding 35m/s.
※ Please indicate in the contract, at exceptionally movement condition.
Description of type
According to the JB/T 8459-2011《Designation for surge arrester products》, the type of MOA shows as below:
Technical parameters
Gapless MOA for distribution
| Technical parameters Product type |
Nominal voltage of system | Rated voltage | Continuous operation voltage | Reference voltage at D.C.1mA k V . D C ≮ | Nominal discharge current kA .peak | Lightning impulse | Steeping impulse | Switching impulse | Parachute diameter Φ mm | Height H mm | Fig. No |
| Residual voltage kV.peak ≯ | |||||||||||
| kV.rms | |||||||||||
| YH5WS-5/15 | 3 | 5 | 4.0 | 7.5 | 5 | 15.0 | 17.3 | 12.8 | 76 | 200 | 1 |
| YH5WS-10/30 | 6 | 10 | 8.0 | 15.0 | 5 | 30.0 | 34.6 | 25.6 | 76 | 200 | 1 |
| YH5WS-12/35.8 | 10 | 12 | 9.6 | 18.0 | 5 | 35.8 | 41.2 | 30.6 | 76 | 255 | 1 |
| YH5WS-15/45.6 | 10 | 15 | 12.0 | 23.0 | 5 | 45.6 | 52.5 | 39.0 | 76 | 255 | 1 |
| YH5WS-17/50 | 10 | 17 | 13.6 | 25.0 | 5 | 50.0 | 57.5 | 42.5 | 76 | 255 | 1 |
Gapless MOA for power station (Part 1)
| Technical parameters Product type |
Nominal voltage of system | Rated voltage | Continuous operation voltage | Reference voltage at D.C.1mA k V . D C ≮ | Nominal discharge current kA .peak | Lightning impulse | Steeping impulse | Switching impulse | Parachute diameter Φ mm | Height H mm | Fig. No |
| Residual voltage kV.peak ≯ | |||||||||||
| kV.rms | |||||||||||
| YH5WZ-5/13.5 | 3 | 5 | 4.0 | 7.2 | 5 | 13.5 | 15.5 | 11.5 | 82 | 200 | 1 |
| YH5WZ-10/27 | 6 | 10 | 8.0 | 14.4 | 5 | 27.0 | 31.0 | 23.0 | 82 | 200 | 1 |
| YH5WZ-12/32.4 | 10 | 12 | 9.6 | 17.4 | 5 | 32.4 | 37.2 | 27.6 | 82 | 255 | 1 |
| YH5WZ-15/40.5 | 10 | 15 | 12.0 | 21.8 | 5 | 40.5 | 46.5 | 34.5 | 82 | 255 | 1 |
| YH5WZ-17/45 | 10 | 17 | 13.6 | 24.0 | 5 | 45.0 | 51.8 | 38.3 | 82 | 255 | 1 |
| Y5WZ-26/66 | 20 | 26 | 20.8 | 37.0 | 5 | 66.0 | 76.0 | 56.0 | 232 | 995 | 5 |
| YH5WZ-26/66 | 114 | 345 | 4 | ||||||||
| Y5WZ-32/85 | 20 | 32 | 25.6 | 47.0 | 5 | 85.0 | 95.0 | 75.0 | 232 | 995 | 5 |
| YH5WZ-32/85 | 114 | 405 | 4 | ||||||||
| Y5WZ-51/134 | 35 | 51 | 40.8 | 73.0 | 5 | 134.0 | 154.0 | 114.0 | 232 | 995 | 5 |
| YH5WZ-51/134 | 114 | 525 | 4 | ||||||||
| Y5WZ-84/221 | 66 | 84 | 67.2 | 121 | 5 | 221 | 254 | 188 | 252 | 1200 | 6 |
| YH5WZ-84/221 | 195 | 1296 | 8 | ||||||||
| Y5WZ-90/235 | 66 | 90 | 72.5 | 130 | 5 | 235 | 270 | 201 | 252 | 1200 | 6 |
| YH5WZ-90/235 | 195 | 1296 | 8 | ||||||||
| Y10WZ-90/235 | 66 | 90 | 72.5 | 130 | 10 | 235 | 264 | 201 | 252 | 1200 | 6 |
| YH10WZ-90/235 | 195 | 1296 | 8 | ||||||||
| Y5WZ-96/250 | 110 | 96 | 75 | 140 | 5 | 250 | 288 | 213 | 270 | 1620 | 7 |
| YH5WZ-96/250 | 195 | 1296 | 8 | ||||||||
| Y10WZ-96/250 | 110 | 96 | 75 | 140 | 10 | 250 | 280 | 213 | 270 | 1620 | 7 |
| YH10WZ-96/250 | 195 | 1296 | 8 | ||||||||
Gapless MOA for power station (Part 2)
| Technical parameters Product type |
Nominal voltage of system | Rated voltage | Continuous operation voltage | Reference voltage at D.C.1mA k V . D C ≮ | Nominal discharge current kA .peak | Lightning impulse | Steeping impulse | Switching impulse | Parachute diameter Φ mm | Height H mm | Fig. No |
| Residual voltage kV.peak ≯ | |||||||||||
| kV.rms | |||||||||||
| Y5WZ-100/260 | 110 | 100 | 78 | 145 | 5 | 260 | 299 | 221 | 270 | 1620 | 7 |
| YH5WZ-100/260 | 195 | 1296 | 8 | ||||||||
| Y10WZ-100/260 | 110 | 100 | 78 | 145 | 10 | 260 | 291 | 221 | 270 | 1620 | 7 |
| YH10WZ-100/260 | 195 | 1296 | 8 | ||||||||
| Y5WZ-102/266 | 110 | 102 | 79.6 | 148 | 5 | 266 | 305 | 226 | 270 | 1620 | 7 |
| YH5WZ-102/266 | 195 | 1296 | 8 | ||||||||
| Y10WZ-102/266 | 110 | 102 | 79.6 | 148 | 10 | 266 | 297 | 226 | 270 | 1620 | 7 |
| YH10WZ-102/266 | 195 | 1296 | 8 | ||||||||
| Y5WZ-108/281 | 110 | 108 | 84 | 157 | 5 | 281 | 323 | 239 | 270 | 1620 | 7 |
| YH5WZ-108/281 | 195 | 1296 | 8 | ||||||||
| Y10WZ-108/281 | 110 | 108 | 84 | 157 | 10 | 281 | 315 | 239 | 270 | 1620 | 7 |
| YH10WZ-108/281 | 195 | 1296 | 8 | ||||||||
| Y10WZ-192/500 | 220 | 192 | 150 | 280 | 10 | 500 | 560 | 426 | 278 | 2880 | 9 |
| YH10WZ-192/500 | 216 | 2635 | 10 | ||||||||
| Y10WZ-200/520 | 220 | 200 | 156 | 290 | 10 | 520 | 582 | 442 | 278 | 2880 | 9 |
| YH10WZ-200/520 | 216 | 2635 | 10 | ||||||||
| Y10WZ-204/532 | 220 | 204 | 159 | 296 | 10 | 532 | 594 | 452 | 278 | 2880 | 9 |
| YH10WZ-204/532 | 216 | 2635 | 10 | ||||||||
| Y10WZ-216/562 | 220 | 216 | 168.5 | 314 | 10 | 562 | 630 | 478 | 278 | 2880 | 9 |
| YH10WZ-216/562 | 216 | 2635 | 10 | ||||||||
| Y10WZ-288/698 | 330 | 288 | 219 | 408 | 10 | 698 | 782 | 593 | 298 | 5100 | 11 |
| YH10WZ-288/698 | 377 | 3850 | 12 | ||||||||
| Y10WZ-300/727 | 330 | 300 | 228 | 425 | 10 | 727 | 814 | 618 | 298 | 5100 | 11 |
| YH10WZ-300/727 | 377 | 3850 | 12 | ||||||||
| Y10WZ-306/742 | 330 | 306 | 233 | 433 | 10 | 742 | 831 | 630 | 298 | 5100 | 11 |
| YH10WZ-306/742 | 377 | 3850 | 12 | ||||||||
| Y10WZ-312/760 | 330 | 312 | 237 | 442 | 10 | 760 | 847 | 643 | 298 | 5100 | 11 |
| YH10WZ-312/760 | 377 | 3850 | 12 | ||||||||
| Y10WZ-324/789 | 330 | 324 | 246 | 459 | 10 | 789 | 880 | 668 | 298 | 5100 | 11 |
| YH10WZ-324/789 | 377 | 3850 | 12 | ||||||||
| Y20WZ-420/1046 | 500 | 420 | 318 | 565 | 20 | 1046 | 1170 | 858 | 418 | 6240 | 11 |
| YH20WZ-420/1046 | 377 | 5850 | 12 | ||||||||
| Y20WZ-444/1106 | 500 | 444 | 324 | 597 | 20 | 1106 | 1238 | 957 | 418 | 6240 | 11 |
| YH20WZ-444/1106 | 377 | 5850 | 12 | ||||||||
| Y20WZ-468/1166 | 500 | 468 | 330 | 630 | 20 | 1166 | 1306 | 630 | 418 | 6240 | 11 |
| YH20WZ-468/1166 | 377 | 5850 | 12 | ||||||||
Gapless MOA for shunt compensating capacitor
| Technical parameters Product type |
Nominal voltage of system | Rated voltage | Continuous operation voltage | Reference voltage at D.C.1mA k V . D C ≮ | Nominal discharge current kA .peak | Lightning impulse | Switching impulse | Parachute diameter Φ mm | Height H mm | Fig. No |
| Residual voltage kV.peak ≯ | ||||||||||
| kV.rms | ||||||||||
| YH5WR-5/13.5 | 3 | 5 | 4.0 | 7.2 | 5 | 13.5 | 10.5 | 88 | 200 | 1 |
| YH5WR-10/27 | 6 | 10 | 8.0 | 14.4 | 5 | 27.0 | 21.0 | 88 | 200 | 1 |
| YH5WR-12/32.4 | 10 | 12 | 9.6 | 17.4 | 5 | 32.4 | 25.2 | 88 | 255 | 1 |
| YH5WR-15/40.5 | 10 | 15 | 12.0 | 21.8 | 5 | 40.5 | 31.5 | 88 | 255 | 1 |
| YH5WR-17/46 | 10 | 17 | 13.6 | 24.0 | 5 | 46.0 | 35.0 | 88 | 255 | 1 |
| Y5WR-26/66 | 20 | 26 | 20.8 | 37.0 | 5 | 66.0 | 53.0 | 232 | 995 | 5 |
| YH5WR-26/66 | 120 | 345 | 4 | |||||||
| Y5WR-32/85 | 20 | 32 | 25.6 | 47.0 | 5 | 85.0 | 68.0 | 232 | 995 | 5 |
| YH5WR-32/85 | 120 | 405 | 4 | |||||||
| Y5WR-51/134 | 35 | 51 | 40.8 | 73.0 | 5 | 134.0 | 105.0 | 232 | 995 | 5 |
| YH5WR-51/134 | 120 | 525 | 4 | |||||||
| Y5WR-84/221 | 66 | 84 | 67.2 | 121 | 5 | 221 | 176 | 252 | 1200 | 6 |
| YH5WR-84/221 | 195 | 1296 | 8 | |||||||
| Y5WR-90/236 | 66 | 90 | 72.5 | 130 | 5 | 236 | 190 | 252 | 1200 | 6 |
| YH5WR-90/236 | 195 | 1296 | 8 | |||||||
| Y10WR-105/265 | 66 | 105 | 84 | 152 | 10 | 265 | 225 | 252 | 1200 | 6 |
| YH10WR-105/265 | 195 | 1296 | 8 | |||||||
| Y10WR-108/281 | 110 | 108 | 84 | 157 | 10 | 281 | 239 | 270 | 1620 | 7 |
| YH10WR-108/28 | 195 | 1296 | 8 | |||||||
| Y10WR-174/372 | 110 | 174 | 139 | 240 | 10 | 372 | 336 | 351 | 2135 | 25 |
| YH10WR-174/372 | 377 | 2200 | 26 | |||||||
Arrester for low voltage system
| Technical parameters Product type |
Nominal voltage of system | Rated voltage | Continuous operation voltage | Reference voltage at D.C.1mA k V . D C ≮ | Nominal discharge current kA .peak | Residual voltage at Lightning current impulse kV.peak | Parachute diameter Φ mm | Height H mm | Fig. No |
| kV.rms | |||||||||
| YH1.5W-0.28/1.3 | 0.22 | 0.28 | 0.24 | 0.6 | 1.5 | 1.3 | 35 | 85 | 2 |
| YH1.5W-0.5/2.6 | 0.38 | 0.5 | 0.42 | 1.2 | 1.5 | 2.6 | 35 | 85 | 2 |
Gapless MOA for motor and generators
| Technical parameters Product type |
Nominal voltage of system | Rated voltage | Continuous operation voltage | Reference voltage at D.C.1mA k V . D C ≮ | Nominal discharge current kA .peak | Lightning impulse | Steeping impulse | Switching impulse | Parachute diameter Φ mm | Height H mm | Fig. No |
| Residual voltage kV.peak ≯ | |||||||||||
| kV.rms | |||||||||||
| YH2.5WD-4/9.5 | 3.15 | 4 | 3.2 | 5.7 | 2.5 | 9.5 | 10.7 | 7.6 | 88 | 200 | 1 |
| YH2.5WD-8/18.7 | 6.3 | 8 | 6.3 | 11.2 | 2.5 | 18.7 | 21.0 | 15.0 | 88 | 200 | 1 |
| YH2.5WD-13.5/31 | 10.5 | 13.5 | 10.5 | 18.6 | 2.5 | 31.0 | 34.7 | 25.0 | 88 | 255 | 1 |
| YH5WD-4/9.5 | 3.15 | 4 | 3.2 | 5.7 | 5 | 9.5 | 10.7 | 7.6 | 88 | 200 | 1 |
| YH5WD-8/18.7 | 6.3 | 8 | 6.3 | 11.2 | 5 | 18.7 | 21.0 | 15.0 | 88 | 200 | 1 |
| YH5WD-13.5/31 | 10.5 | 13.5 | 10.5 | 18.6 | 5 | 31.0 | 34.7 | 25.0 | 88 | 255 | 1 |
| YH5WD-17.5/40 | 13.8 | 17.5 | 13.8 | 24.4 | 5 | 40.0 | 44.8 | 32.0 | 88 | 255 | 1 |
| YH5WD-20/45 | 15.75 | 20 | 15.8 | 28.0 | 5 | 45.0 | 50.4 | 36.0 | 88 | 255 | 1 |
| YH5WD-23/51 | 18.0 | 23 | 18.0 | 31.9 | 5 | 51.0 | 57.2 | 40.8 | 88 | 310 | 1 |
| YH5WD-25/56.2 | 20.0 | 25 | 20.0 | 35.4 | 5 | 56.2 | 62.9 | 45.0 | 88 | 310 | 1 |
※Note:The arrester which nominal discharge current is 2.5kA used for protection of Motor.
The arrester which nominal discharge current is 5kA used for protection of Generators.
The arrester which nominal discharge current is 5kA used for protection of Generators.
Gapless MOA with Polymer-housed for transmission lines
| Technical parameters Product type |
Nominal voltage of system | Rated voltage | Continuous operation voltage | Reference voltage at D.C.1mA k V . D C ≮ | Nominal discharge current kA .peak | Lightning impulse | Steeping impulse | Switching impulse | Parachute diameter Φ mm | Height H mm | Fig. No |
| Residual voltage kV.peak ≯ | |||||||||||
| kV.rms | |||||||||||
| YH5WX-34/90 | 20 | 34 | 27.2 | 50.0 | 5 | 90.0 | 104.0 | 80.0 | 114 | 475 | 13 |
| YH5WX-51/134 | 35 | 51 | 40.8 | 73.0 | 5 | 134.0 | 154.0 | 114.0 | 114 | 595 | 13 |
| YH⁵WX-54/L49 | 35 | 54.0 | 43.2 | 77.0 | 5 | 142.0 | 163.0 | 121.0 | 114 | 595 | 13 |
| YH5WX-54/150 | 35 | 54.0 | 43.2 | 80.0 | 5 | 150.0 | 169.0 | 128.0 | 114 | 595 | 13 |
| YH5WX-96/250 | 66 | 96 | 75 | 140 | 5 | 250 | 288 | 213 | 195 | 1355 | 14 |
| YH5WX-96/275 | 66 | 96 | 75 | 154 | 5 | 275 | 316 | 234 | 195 | 1355 | 14 |
| YH5WX-108/281 | 110 | 108 | 84 | 157 | 5 | 281 | 323 | 239 | 195 | 1355 | 14 |
| YH5WX-108/300 | 110 | 108 | 84 | 173 | 5 | 309 | 348 | 263 | 195 | 1355 | 14 |
| YH1OWX-108/281 | 110 | 108 | 84 | 157 | 10 | 281 | 315 | 239 | 195 | 1355 | 14 |
| YH10WX-108/309 | 110 | 108 | 84 | 173 | 10 | 309 | 348 | 263 | 195 | 1355 | 14 |
| YH10WX-216/562 | 220 | 216 | 168 | 314 | 10 | 562 | 630 | 478 | 195 | 2685 | 15 |
| YH10WX-216/618 | 220 | 216 | 168.5 | 346 | 10 | 618 | 693 | 526 | 195 | 2685 | 15 |
| YH10WX-312/760 | 330 | 312 | 237 | 442 | 10 | 760 | 847 | 643 | 216 | 3530 | 16 |
| YH10WX-324/789 | 330 | 324 | 246 | 459 | 10 | 789 | 880 | 668 | 216 | 3530 | 16 |
| YH20WX-468/1166 | 500 | 468 | 330 | 630 | 20 | 1166 | 1306 | 630 | 377 | 5850 | 12 |
Gapless MOA for electrical railway
| Technical parameters Product type |
Nominal voltage of system | Rated voltage | Continuous operation voltage | Reference voltage at D.C.1mA k V . D C ≮ | Nominal discharge current kA .peak | Lightning impulse | Steeping impulse | Switching impulse | Parachute diameter Φ mm | Height H mm | Fig. No |
| Residual voltage kV.peak ≯ | |||||||||||
| kV.rms | |||||||||||
| Y5WT-42/105 | 27.5 | 42 | 31.5 | 58.0 | 5 | 105.0 | 118.0 | 89.0 | 232 | 995 | 5 |
| YH5WT-42/105 | 128 | 525 | 4 | ||||||||
| Y5WT-42/110 | 27.5 | 42 | 31.5 | 60.0 | 5 | 110.0 | 127.0 | 94.0 | 232 | 995 | 5 |
| YH5WT-42/110 | 128 | 525 | 4 | ||||||||
| Y5WT-42/120 | 27.5 | 42 | 34.0 | 65.0 | 5 | 120.0 | 138.0 | 98.0 | 232 | 995 | 5 |
| YH5WT-42/120 | 128 | 525 | 4 | ||||||||
| Y5WT-84/240 | 55 | 84 | 68 | 130 | 5 | 240 | 276 | 196 | 252 | 1200 | 6 |
| YH5WT-84/240 | 195 | 1296 | 8 | ||||||||
| Y5WT-100/260 | 110 | 100 | 73 | 145 | 5 | 260 | 291 | 221 | 270 | 1620 | 7 |
| YH5WT-100/260 | 195 | 1296 | 8 | ||||||||
| Y5WT-100/275 | 110 | 100 | 73 | 150 | 5 | 275 | 316 | 234 | 270 | 1620 | 7 |
| YH5WT-100/275 | 195 | 1296 | 8 | ||||||||
| Y10WT-100/290 | 110 | 100 | 73 | 158 | 10 | 290 | 325 | 247 | 270 | 1620 | 7 |
| YH10WT-100/290 | 195 | 1296 | 8 | ||||||||
| Y10WT-100/295 | 110 | 100 | 73 | 160 | 10 | 295 | 330 | 251 | 270 | 1620 | 7 |
| YH10WT-100/295 | 195 | 1296 | 8 | ||||||||
Gapless MOA for electrical machinery neutral point
| Technical parameters Product type |
Rated voltage of electrical machinery | Rated voltage | Continuous operation voltage | Reference voltage at D.C.1mA k V . D C ≮ | Nominal discharge current kA .peak | Lightning impulse | Switching impulse | Parachute diameter Φ mm | Height H mm | Fig. No |
| Residual voltage kV.peak ≯ | ||||||||||
| kV.rms | ||||||||||
| YH1.5W-2.4/6 | 3.15 | 2.4 | 1.9 | 3.4 | 1.5 | 6.0 | 5.0 | 88 | 200 | 1 |
| YH1.5W-4.8/12 | 6.3 | 4.8 | 3.8 | 6.8 | 1.5 | 12.0 | 10.0 | 88 | 200 | 1 |
| YH1.5W-8/19 | 10.5 | 8 | 6.4 | 11.4 | 1.5 | 19.0 | 15.9 | 88 | 200 | 1 |
| YH1.5W-10.5/23 | 13.8 | 10.5 | 8.4 | 14.9 | 1.5 | 23.0 | 19.2 | 88 | 200 | 1 |
| YH1.5W-12/26 | 15.75 | 12 | 9.6 | 17.0 | 1.5 | 26.0 | 21.6 | 88 | 200 | 1 |
| YH1.5W-13.7/29.2 | 18.0 | 13.7 | 11.0 | 19.5 | 1.5 | 29.2 | 24.3 | 88 | 255 | 1 |
| YH1.5W-15.2/31.7 | 20.0 | 15.2 | 12.2 | 21.6 | 1.5 | 31.7 | 26.4 | 88 | 255 | 1 |
MOA with parallel gaps for electrical machinery
| Technical parameters Product type |
Rated voltage of electrical machinery | Rated voltage | Continuous operation voltage | Reference voltage at D.C.1mA k V . D C ≮ | Nominal discharge current kA .peak | Residual voltage at Nominal discharge current kV.peak ≯ | Parachute diameter Φ mm | Height H mm | Fig. No |
| kV.rms | |||||||||
| YH0.5B-8/11 | 6.3 | 8 | 6.3 | 11.5 | 0.5 | 11.0 | 88 | 255 | 1 |
| YH0.5B-13.5/20 | 10.5 | 13.5 | 10.5 | 21.0 | 0.5 | 20.0 | 88 | 255 | 1 |
Gapless MOA for transformer neutral point
| Technical parameters Product type |
Nominal voltage of system | Rated voltage | Continuous operation voltage | Reference voltage at D.C.1mA k V . D C ≮ | Nominal discharge current kA .peak | Lightning impulse | Switching impulse | Parachute diameter Φ mm | Height H mm | Fig. No |
| Residual voltage kV.peak ≯ | ||||||||||
| kV.rms | ||||||||||
| Y1.5W-30/98 | 35 | 30 | 24.0 | 61.0 | 1.5 | 98.0 | 88.0 | 232 | 995 | 5 |
| YH1.5W-30/98 | 120 | 525 | 4 | |||||||
| Y1.5W-60/144 | 110 | 60 | 48 | 85 | 1.5 | 144 | 135 | 232 | 1145 | 5 |
| YH1.5W-60/144 | 142 | 585 | 4 | |||||||
| Y1.5W-72/186 | 110 | 72 | 58 | 103 | 1.5 | 186 | 174 | 110 | 215 | 5 |
| YH1.5W-72/186 | 142 | 585 | 4 | |||||||
| Y1.5W-96/260 | 500 | 96 | 77 | 137 | 1.5 | 260 | 243 | 270 | 1620 | 7 |
| YH1.5W-96/260 | 195 | 1296 | 8 | |||||||
| Y1.5W-144/320 | 220 | 144 | 116 | 205 | 1.5 | 320 | 299 | 270 | 1620 | 7 |
| YH1.5W-144/320 | 195 | 1296 | 8 | |||||||
| Y1.5W-210/440 | 330 | 210 | 168 | 285 | 1.5 | 440 | 410 | 278 | 2880 | 9 |
| YH1.5W-210/440 | 216 | 2635 | 10 | |||||||
MOA with series gap
| Technical parameters Product type |
Rated voltage of electrical machinery | Rated voltage | Continuous operation voltage | Power frequency discharge voltage kV.rms ≮ | Discharge voltage at impulse 1.2/50μS kV.peak ≯ | Nominal discharge current kA .peak | Lightning impulse | Steeping impulse | Parachute diameter Φ mm | Height H mm | Fig. No |
| Residual voltage kV.peak ≯ | |||||||||||
| kV.rms | |||||||||||
| YH5CS-3.8/15 | 3 | 3.8 | 3.0 | 9.0 | 21.0 | 5 | 15.0 | 17.2 | 82 | 200 | 1 |
| YH5CS-7.6/27 | 6 | 7.6 | 6.1 | 16.0 | 35.0 | 5 | 27.0 | 31.0 | 82 | 200 | 1 |
| YH5CS-12.7/45 | 10 | 12.7 | 10.2 | 26.0 | 50.0 | 5 | 45.0 | 51.8 | 82 | 255 | 1 |
| YH5CZ-3.8/12 | 3 | 3.8 | 3.0 | 9.0 | 20.0 | 5 | 12.0 | 13.8 | 82 | 200 | 1 |
| YH5CZ-7.6/24 | 6 | 7.6 | 6.1 | 16.0 | 30.0 | 5 | 24.0 | 27.6 | 82 | 200 | 1 |
| YH5CZ-12.7/41 | 10 | 12.7 | 12.7 | 26.0 | 45.0 | 5 | 41.0 | 47.2 | 82 | 255 | 1 |
| YH5CZ-42/124 | 35 | 42 | 33.6 | 80.0 | 134.0 | 5 | 124.0 | 142.6 | 114 | 585 | 4 |
| YH2.5CD-3.8/9.5 | 3.15 | 3.8 | 3.0 | 7.5 | 9.5 | 2.5 | 9.5 | 10.7 | 88 | 200 | 1 |
| YH2.5CD-7.6/18.7 | 6.3 | 7.6 | 6.1 | 15.0 | 18.7 | 2.5 | 18.7 | 21.0 | 88 | 200 | 1 |
| YH2.5CD-12.7/3 | 10.5 | 12.7 | 10.2 | 25.0 | 31.0 | 2.5 | 31.0 | 34.7 | 88 | 255 | 1 |
| YH5CD-3.8/9.5 | 3.15 | 3.8 | 3.0 | 7.5 | 9.5 | 5 | 9.5 | 10.7 | 88 | 200 | 1 |
| YH5CD-7.6/18.7 | 6.3 | 7.6 | 6.1 | 15.0 | 18.7 | 5 | 18.7 | 21.0 | 88 | 200 | 1 |
| YH5CD-12.7/31 | 10.5 | 12.7 | 10.2 | 25.0 | 31.0 | 5 | 31.0 | 34.7 | 88 | 255 | 1 |
※Note:The arrester which nominal discharge current is 2.5kA used for protection of Motor.
The arrester which nominal discharge current is 5kA used for protection of Generators.
The arrester which nominal discharge current is 5kA used for protection of Generators.
Polymer-housed MOA with gaps for transmission lines
| Technical parameters Product type |
Nominal voltage of system | Rated voltage | Reference voltage at D.C.1mA of units k V . D C ≮ | Power frequency withstand voltage kV.rms ≯ | 50% Lightning impulse sparkover voltage kV.peak ≯ | Nominal discharge current kA .peak | Lightning impulse | Steeping impulse | Parachute diameter Φ mm | Height H mm | Fig. No |
| Residual voltage kV.peak ≯ | |||||||||||
| kV.rms | |||||||||||
| YH5CX-13/40 | 10 | 13 | 20.0 | 26 | 100 | 5 | 40.0 | 46.0 | 76 | 185 | 17 |
| YH5CX-42/120 | 35 | 42 | 60.0 | 70 | 240 | 5 | 120.0 | 138.0 | 120 | 545 | 18 |
| 120 | 960 | 19 | |||||||||
| YH5CX-75/218 | 66 | 75 | 108 | 117 | 400 | 5 | 218 | 246 | 195 | 910 | 20 |
| 195 | 1600 | 21 | |||||||||
| YH5CX-90/260 | 110 | 90 | 130 | 170 | 525 | 5 | 260 | 292 | 195 | 975 | 20 |
| 195 | 2035 | 21 | |||||||||
| YH10CX-90/260 | 110 | 90 | 130 | 170 | 525 | 10 | 260 | 292 | 195 | 975 | 20 |
| 195 | 2035 | 21 | |||||||||
| YH10CX-96/280 | 110 | 96 | 140 | 170 | 525 | 10 | 280 | 314 | 195 | 975 | 20 |
| 195 | 2035 | 21 | |||||||||
| YH10CX-102/296 | 110 | 102 | 148 | 170 | 525 | 10 | 296 | 332 | 195 | 975 | 20 |
| 195 | 2035 | 21 | |||||||||
| YH10CX-180/520 | 220 | 180 | 260 | 340 | 900 | 10 | 520 | 584 | 195 | 1655 | 20 |
| 195 | 3450 | 21 | |||||||||
| YH10CX-192/560 | 220 | 192 | 280 | 340 | 900 | 10 | 560 | 628 | 195 | 1655 | 20 |
| 195 | 3450 | 21 | |||||||||
| YH10CX-204/592 | 220 | 204 | 296 | 340 | 900 | 10 | 592 | 664 | 195 | 1655 | 20 |
| 195 | 3450 | 21 | |||||||||
| YH10CX-288/775 | 330 | 288 | 408a | 460 | 1300 | 10 | 775 | 868 | 195 | 2450 | 22 |
| YH20CX-396/1050 | 500 | 396 | 561 | 510 | 1760 | 20 | 1050 | 1171 | 216 | 3600 | 23 |
※Note: Reference voltage at D.C. 2mA.
The structure and installation dimensional drawing
Frequently Asked Questions (FAQ)
What are the main advantages of a polymer-housed metal-oxide surge arrester?
It combines the benefits of organic insulating materials and traditional porcelain-clad techniques. Key features include outstanding insulation, high dielectric strength, anti-leaking, resistance to electrical corrosion, heat and cold resistance, anti-aging properties, explosion-proof construction, hydrophobic properties, and excellent sealing.
What are the normal environmental limits for operating these surge arresters?
They are designed to operate in ambient temperatures between -40℃ and +40℃, at altitudes not exceeding 2600 meters, under maximum wind speeds of 35m/s, and in areas with an earthquake intensity of 8 degrees or less.
What A.C. power supply frequency range is compatible with these arresters?
The normal service condition frequency for the A.C. power supply must be no less than 48Hz and must not exceed 62Hz.
How do you choose between a 2.5kA and a 5kA nominal discharge current arrester for machinery?
According to the technical parameters, surge arresters with a nominal discharge current of 2.5kA are specifically used for the protection of motors, while those with a nominal discharge current of 5kA are designed for the protection of generators.
Are these surge arresters designed according to international standards?
Yes, they are designed and manufactured strictly in accordance with international IEC standards and national GB standards, achieving clear performance advantages over competitive international products.
What should be specified if the installation conditions are outside the normal limits?
If you expect exceptionally high movement, severe vibrations, or environmental conditions exceeding the normal thresholds (such as higher altitude or extreme temperatures), please clearly indicate these requirements in the contract.