The VS1 (VTDseries Indoor High Voltage AC Vacuum Circuit Breaker, produced in China, is designed for switchgears operating at rated voltages of 12-24kV. This circuit breaker is essential for protecting and controlling electrical equipment in various industries, including mining enterprises, power plants, and substations. One of its key advantages is its capability to handle frequent operations at rated current and multiple short-circuit currents, making it an ideal choice for demanding applications.

,

Manufactured by leading suppliers, the circuit breaker features an integrated design that combines the operating mechanism and the circuit breaker itself. This innovative structure consists of a front and rear sub-assembly, ensuring reliable interlocking functionality. The unit can be utilized as either a fixed installation or a handcart unit with a chassis, providing versatility for various installation needs. As a trusted factory in the industry, we ensure high-quality standards in our products.

    General

    VS1 (VTD6) series Indoor high voltage AC vacuum circuit breaker is applicable to switchgears with rated voltage of 12~24kV. It's used for protecting and controlling the electrical equipment in the fields of industry & mining enterprise, power plants and substation. Due to the special advantages of vacuum circuit breakers, it is especially suitable for applications requiring frequent operations at rated current or multiple short-circuit currents.

    The circuit breaker adopts the integrated design of operating mechanism and circuit breaker. They form a front and rear sub assembly structure with reliable interlocking function. It can be used as a fixed installation unit or a handcart unit with a chassis.

    Standards

    Product quality assurance is based on the continuous improvement of product research, development, design and production processes that meet the requirements of all aspects of the quality system. The basic parameters and technical indicators of the product meet the following standards.

    GB/T1984 High voltage AC circuit breaker
    DL/T403 High voltage AC circuit breaker
    IEC60694 Common specifications for high-voltage switchgear and controlgear standards
    IEC62271-100 High-voltage switchgear and controlgear-Part 100: Alternating current circuit breakers

    Service Conditions

    • Ambient temperature: - 15 ℃ ~ + 40 ℃
    • Altitude: ≤ 1000M
    • Relative humidity: Daily average relative humidity ≤ 95%
    • Daily average vapor pressure ≤ 2.2x10-3MPa
    • Monthly average relative humidity ≤ 90%
    • Monthly average vapor pressure ≤ 1.8x10-3MPa
    • Earthquake resistant level: < grade 8 3.
    • Site condition: no dripping, no flammable and explosive hazards, no chemical corrosive gas and no violent vibration
    ※Note: If the service environment exceeds the above conditions, please consult with the manufacturer.

    Type and Designation

    Type and Designation

    Technical Data

    ◆ Technical parameters of circuit breaker
    Item Unit Parameters
    Rated voltage kV 12 24
    Rated frequency Hz 50/60
    1min Rated power frequency short-time withstand voltage (phase to phase, to earth / isolation distance) kV 42 65
    Rated Lightning impulse withstand voltage (peak) (phase to phase, to earth / isolation distance) kV 75 125
    Rated operation sequence   O-t-CO-t'-CO
    Item Unit Parameters
    Rated current A 630 1250 1250 1600 2000 2500 1250 1600 2000 2500 3150 3150 4000
    Rated short-time breaking current kA 20/25 31.5 40 50
    Rated short-circuit making current (peak) kA 50/63 80 100 125
    Rated short-circuit duration S 4 4 4 4
    Mechanical life Times 20000 20000 20000 10000
    Note:
    20kA   25kA   31.5kA   t=0.3s   t’=180s
    40kA   50kA   t=180s   t’=180s
    4000A requires forced air cooling
    ※ If the mechanical life requirement is higher than the standard configuration, consult with the manufacturer.
    ◆ Mechanical characteristic parameters of circuit breaker
    Item Unit Parameters
    12KV 24KV
    Distance of contact mm 9 ± 1 13 ± 1
    Over-travel mm 3.5±0.5
    Three-phase C/O asynchrony ms ≤2
    Closing contact bounce time ms ≤2/≤3(50kA)
    Contact pressure of closing contact N 20kA 25kA 31.5kA 40kA 50kA
    2000 ± 200 2400 ± 200 3100 ± 200 4250 ± 200 5500 ± 200
    Average opening speed m/s 0.9~1.31 1.1~1.6
    Average closing speed m/s 0.4~0.8 0.6~1.0
    ◆ Opening and closing time
    Closing time: 30~70ms Opening time: 15~45ms
    ◆ Technical parameters of coil and locking electromagnet
    Name of equipment Power (W) Rated voltage (V)
    Opening coil 368 220/110
    Closing coil 368
    Locking electromagnet 4.8
    Overcurrent controller Y7 (Y8, Y9)
    ◆ Technical parameters of energy charging motor
    Rated voltage (V) Power (W) Charging time (s) Applicable current class
    220/110 70 ≤15 20kA、25kA、31.5kA、40kA
    220/110 90 ≤15 50kA

    Outline dimension drawing

    A) Fixed type - 12kV
    Outline drawing 1
    Rated current(A) 630 / 1250 / 1600
    Rated breaking current (A) 20, 25, 31.5 / 25, 31.5 / 31.5, 40
    Distance between phases 150 ± 1.5 mm
    Top interlock L1 30, 50 mm
    Spindle interlock L2 30, 50 mm
    Outline dimension drawing of VS1 (VTD6)-12 fixed type circuit breaker (Distance between phases is 150mm)
    Outline drawing 2
    Rated current (A) 630 / 1250 / 1600
    Rated breaking current (A) 20, 25, 31.5 / 25, 31.5 / 31.5, 40
    Distance between phases 210 ± 1.5 mm
    Top interlock L1 30, 50 mm
    Spindle interlock L2 30, 50 mm
    Outline dimension drawing of VS1 (VTD6)-12 fixed type circuit breaker (Distance between phases is 210mm)
    *Dimension in brackets refers to distance from outgoing terminal of composite insulated pole to center of pole.
    Outline drawing 3
    Rated current (A) 630 / 1250 / 1600
    Rated breaking current (A) 20, 25, 31.5 / 25, 31.5 / 31.5, 40
    Distance between phases 210 ± 1.5 mm
    Top interlock L1 30, 50 mm
    Spindle interlock L2 30, 50 mm
    Outline dimension drawing of VS1 (VTD6)-12 fixed type circuit breaker (Distance between phases is 275mm)
    B) Withdrawable type - 12kV (trolley travel distance is 200mm)
    Withdrawable drawing 1
    Rated current (A) 630 / 1250
    Rated breaking current (A) 20, 25, 31.5 / 25, 31.5
    Static contact dimension Φ35 / Φ49 mm
    Distance between phases 150 ± 1.5 mm
    Outline dimension drawing of VS1 (VTD6)-12 withdrawable type circuit breaker (For cabinet width 550mm)
    Withdrawable drawing 2
    Rated current (A) 630 / 1250 / 1600
    Rated breaking current (A) 20, 25, 31.5 / 25, 31.5, 40 / 31.5, 40
    Static contact dimension Φ35 / Φ49 / Φ55 mm
    Distance between phases 150 ± 1.5 mm
    Outline dimension drawing of VS1 (VTD6)-12 withdrawable type circuit breaker (For cabinet width 650mm)
    Withdrawable drawing 3
    Rated current (A) 630 / 1250 / 1600
    Rated breaking current (A) 20, 25, 31.5 / 25, 31.5, 40 / 31.5, 40
    Static contact dimension Φ35 / Φ49 / Φ55 mm
    Distance between phases 210 ± 1.5 mm
    Outline dimension drawing of VS1 (VTD6)-12 withdrawable type circuit breaker (For cabinet width 880mm)
    Withdrawable drawing 4
    Rated current (A) 1600 / 2000 / 2500 / 3150 / 4000
    Rated breaking current (A) 31.5, 40 / 31.5, 40 / 31.5, 40 / 31.5, 40 / 40, 50
    Static contact dimension Φ79 / Φ79 / Φ109 / Φ109 / Φ109 mm
    Distance between phases 275 ± 1.5 mm
    Outline dimension drawing of VS1 (VTD6)-12 withdrawable type circuit breaker (For cabinet width 1000mm)
    C) Fixed type - 24kV
    Fixed 24kV drawing 1
    Rated current (A) 630 / 1250 / 1600
    Rated breaking current (A) 20, 25, 31.5 / 25, 31.5, 40
    Distance between phases 275 ± 1.5 mm
    Top / Spindle interlock 30, 50 mm
    Outline dimension drawing of VS1 (VTD6)-24 fixed type circuit breaker (Distance between phases is 275mm)
    * Note: Outgoing conductive surface of 1600A fixed & sealed pole and transition block provided by customer. Dimension in brackets is from outgoing terminal of composite insulated pole to center of pole.
    Fixed 24kV drawing 2
    Rated current (A) 1600 / 2000 / 2500 / 3150
    Rated breaking current (A) 31.5, 40
    Distance between phases 275 ± 1.5 mm
    Top / Spindle interlock 30, 50 mm
    Outline dimension drawing of VS1 (VTD6)-24 fixed type circuit breaker (Distance between phases is 275mm)
    D) Withdrawable type - 24kV (trolley travel distance is 300mm)
    Withdrawable 24kV drawing 1
    Rated current (A) 630 / 1250 / 1600
    Rated breaking current (A) 20, 25, 31.5 / 25, 31.5, 40 / 31.5, 40
    Static contact dimension Φ35 / Φ49 / Φ55 mm
    Distance between phases 275 ± 1.5 mm
    Outline dimension drawing of VS1 (VTD6)-24 withdrawable type circuit breaker (For cabinet width 1000mm)
    Withdrawable 24kV drawing 2
    Rated current (A) 1600 / 1600 / 2000 / 2500 / 3150
    Rated breaking current (A) 31.5, 40 / 31.5, 40 / 31.5, 40 / 31.5, 40 / 31.5, 40
    Static contact dimension Φ55 / Φ79 / Φ79 / Φ109 / Φ109 mm
    Distance between phases 275 ± 1.5 mm
    Outline dimension drawing of VS1 (VTD6)-24 withdrawable type circuit breaker (For cabinet width 1000mm)

    Frequently Asked Questions (FAQ)

    Q1: What is the rated voltage range for the VS1 (VTD6) series vacuum circuit breaker?
    A1: The VS1 (VTD6) series is designed for indoor high voltage AC switchgears with a rated voltage range of 12kV to 24kV.
    Q2: Which international and local standards do these circuit breakers comply with?
    A2: The product meets the requirements of GB/T1984, DL/T403, IEC60694, and IEC62271-100 standards.
    Q3: What are the environmental limits for operating the VS1 (VTD6) vacuum circuit breaker?
    A3: The standard service conditions require an ambient temperature between -15℃ and +40℃, an altitude of ≤ 1000m, daily average relative humidity ≤ 95%, and an earthquake resistant level below grade 8.
    Q4: Does the 4000A current class require special cooling methods?
    A4: Yes, the 4000A rated current configuration requires forced air cooling to maintain optimal operating temperatures.
    Q5: What is the typical mechanical life of the circuit breaker?
    A5: The mechanical life is rated up to 20,000 operations for standard models, and 10,000 operations for the 50kA rated short-time breaking current model. Higher specifications can be consulted with the manufacturer.
    Q6: Can this circuit breaker be installed in environments exceeding standard service conditions?
    A6: If your operational environment exceeds standard limits (e.g., altitude higher than 1000m or extreme temperatures), please consult directly with the manufacturer for custom technical configurations.