China XGTD8-12 Indoor N₂ Gas Insulation Metal-clad Switchgear Suppliers and Factory - Eco-friendly Solution

General
Introducing the XGTD8-12 indoor environmental gas-insulated metal-clad switchgear, a cutting-edge electrical solution proudly manufactured in China. As a leading supplier in the industry, our switchgear is designed with eco-friendly gas technology to provide sustainable and reliable performance. This compact and rationally designed switchgear boasts maintenance-free operation, an extended service life, and exceptional adaptability to diverse environmental conditions, making it an ideal choice for various applications. Trust our factory to deliver top-quality products that meet your electrical needs while prioritizing environmental responsibility.

    Detail introduction

    The switchgear and its primary live parts are enclosed within a stainless steel shell, effectively shielding them from external influences. It employs a modular design, allowing for flexible combinations of common-tank and extended-unit configurations to meet various schemes and arrangements. This design ensures that the switchgear can satisfy the demands of compact installations in secondary transmission and distribution substations.
    Moreover, the switchgear is widely applicable in a range of environments, including secondary small distribution substations, industrial and mining enterprises, airports, railways, commercial districts, high-rise buildings, highways, subways, tunnels, and other locations with severe conditions.
    The product's quality assurance is grounded in a robust quality system that governs research, development, design, and production. Continuous improvement is a key focus, ensuring that the switchgear fully complies with the latest versions or revisions of relevant standards—though not limited to them.
    IEC62271-200 AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV.
    EN50181 Insertion bushings for equipment rated at voltages from 1 kV to 52 kV and currents from 250 A to 2500 A.
    GB/T3906 AC metal-enclosed switchgear and controlgear for rated voltages above 3.6 kV and up to and including 40.5 kV
    GB/T11022 Common specifications for high-voltage switchgear and controlgear standards
    DL/T404 AC metal-enclosed switchgear and controlgear for rated voltages above 3.6 kV and up to and including 40.5 kV
    GB/T1984 High voltage AC circuit breaker
    GB/T1985 High-voltage alternating-current isolators and earthing switches.
    GB/T20840 Instrument transformers - Part 1: General requirements.
    GB/T11032 AC Metal oxide surge arresters without gaps

    Service Conditions

    • a. Ambient temperature: -45℃~+50℃ the daily average value shall not exceed 35℃;
    • b. Altitude: Not more than 4000m(If the equipment working over 1000m,please note it for the convenience of adjustment to the inflation pressure);
    • c. Relative humidity: Daily average is not more than 95%,Monthly average is not more than 90%;
    • d. Seismic grade: The seismic intensity shall not exceed grade 8;
    • e. Pollution: There shall be no Corrosive, flammable gases or other pollution.
    ※Note: if the service environment exceeds the above conditions, please consult with our company.

    Technical parameter

    Item Unit Parameters
    V: CB unit C: load switch unit
    Rated voltage kV 12
    Rated current A 630/1250 630
    Rated frequency Hz 50/60
    1 min rated power frequency withstand voltage (rms) Phase to Phase/Phase to earth kV 42
    Insulation Distance 48
    Rated Lightning impulse withstand voltage(peak) Phase to Phase/Phase to earth kV 75
    Insulation Distance 85
    Rated power frequency withstand voltage of auxiliary circuit kV 2
    Rated short circuit breaking current(rms) kA 20/25
    Rated short circuit making current (peak) kA 50/63
    Rated short time withstand current (4s) kA 20/25
    Rated peak withstand current kA 50/63
    Main circuit resistance of each phase μΩ ≤160
    N₂ gas rated operation pressure MPa 0.02
    Mechanical life CB/Load switch times 10000
    Three-position switch 5000
    Rated values of internal arc level (IAC) KA/S 25/1
    Annual leak rate of N₂ gas % ≤0.1
    Protection degrees / IP67 for gas-filled compartment, IP4X for others

    Product Features and Structure

    ● Product features
    ● Green and environment-friendly
    Rather than SF6, all the nitrogen or dry air insulation, vacuum extinction, no greenhouse gas emissions. Harmful chemical elements in raw materials are strictly controlled in the parts manufacturing process, which can reduce the production of harmful substances. And the recycle rate of materials can reach 90% after the retirement.
    ● Safe and reliable
    It adopts micro-positive pressure gas insulation to reduce the leak rate of gas. Although, leaking happen to the gas compartment, it can still keep enough insulation ability at the lowest functional pressure, and does not affect the normal operating.
    ● Reasonable design
    ● Modular design
    The switchgear includes load switch unit, the circuit breaker unit(V), meter switchgear unit(M), bus PT units,etc.it can achieve many forms of combination through general full insulation and full shielding bus connection, which can meet the demand for different places, different forms, different needs of customers, and provide a variety of designs for power supply and distribution.
    ● Fully insulated and sealed design
    The primary live part(main bus)of the switchgear and switch itself are sealed in the gas tank of welded stainless steel plate. The main circuit is connected to external through DIN47636 standard bushing that installed on the gas tank. It can also be connected to input and output cable by full insulation, shielding all full sealed separable connector. And protection grade of the gas tank box reach IP67. The inside of the gas tank is not affected by the external environment. It also has the short-term resistance function of flood and condensation.
    ● The other
    User interface and cable connection are located in the front of the body,which is convenient for user operation. Operation switchgear instructions are clear, simple and easy to understand. The status of the three-station switch can be observed through the switchgear observation window.
    ● Small volume
    Adopting the insulation of environment-friendly gas, retained the size advantage of gas insulation switchgear, size is small, which can saving the floor area.
    ● Less maintenance
    High voltage insulation is not influenced by the external environment,and hardly aging. There is no need for users to protect or detect weather the SF6 gas leaks. Also, it can reduce the total life cycle cost of the product.
    ● Strong adaptability to environment
    All the HV components are sealed in the gas-filled metal enclosure, and the switchgear is especially suitable for high altitude, cold, damp, salt mist, pollution and other harsh environment.
    ● Product structure
    ● Outline structure
    product description01
    Secondary meter room: For installing secondary components such as Ammeter, Voltmeter, protection device, gathering the secondary terminal of switchgear, which is convenient for maintenance and operation.
    Live display: To provide the live display data for input and output of cables.
    Gas-pressure meter: To show the safe pressure range in gas tank, and alarm contact function can be selected to achieve the operation of interlock opening and closing at low gas pressure.
    Operation switchgear: To provide switch operating indications of opening and closing, on which the corresponding switch operating instructions were printed.
    Gas tank compartment: It is fully sealed designed, which welded with the high quality stainless steel welding, and reach IP67 degree of protection.
    Pressure relief compartment: For installation cable and current transformer.At the same time,it's the guide channel for arching pressure relief, which may lead the arc to the cable trench.
    Cable room front door: It's the entrance of cable compartment,and it shall betaken apart first.
    Note: the connection of the figure between compartments is the outer cone top connection.
    ● Outline structure
    product description02
    Type Width(W) Height(H) Depth(D)
    C Top connection 420mm 1950mm 850mm
    Side connection 420mm 2000mm
    V Top connection 420mm 1950mm
    Side connection 420mm 2000mm
    PT Top connection 600mm 1950mm
    Side connection 600mm 2000mm
    D Top connection 420mm 1950mm
    Side connection 420mm 2000mm
    Note: the connection of the figure between compartments is the inner cone side connection, which also can be outer cone top connection as user demanded.

    Operation

    ● Operation procedures
    ● Preparation before operation
    It shall be operated with specific handle,and confirm that the installation of cable compartment front door and the correct connection of HV cable and secondary circuit.
    ● Power on operation procedure
    Ensure that circuit breaker/load switch in open position (which rotate the opening switch to open the circuit breaker/load switch), open the three position switch from earthing closing position to opening position, then operate it from isolation position to closing position. Operating isolation switch lively is forbidden. After confirming the isolation switch is closed,charging the circuit breaker/load switch mechanism with operating handle. Then rotate the closing knob, closing the circuit breaker/load switch.
    Note: There is mechanical interlock between circuit breaker/load switch mechanism and isolation mechanism to prevent mistake operation. If some operating difficulties happen, please check the condition of circuit breaker/load switch, and then do the closing or openng operation rather than operate forcibly.
    ● Power off operation procedure
    Rotate the closing knob,open the circuit breaker/load switch.Then operate the three position switch from isolation closing position to opening position with handle.
    ● Inspection operation procedure
    After confirming the cable compartment is not live,operate the three position switch from earthing opening position to closing position. Then open the front door for inspection.
    product description03
    ● Interlock logic
    • a. Only when earthing switch at closing position,circuit breaker/load switch at opening position, can the cable compartment front door be opened.
    • b. The earthing switch cannot be operated when the front door is open.
    • c. The isolation switch and earthing switch cannot be operated when circuit breaker/load switch at closing position.
    • d. When operate isolation switch and earthing switch, circuit breaker/load switch at closing position can not be operated.
    • e. Only when circuit breaker/load switch at closing position can the cable compartment front door closed.

    Principle of Secondary Circuit

    ● Secondary circuit principle of the cabinet
    product description04
    ● Secondary circuit principle of the circuit breaker
    product description05

    Scheme Option Table

    Single cabinet type
    product description06
    product description07
    Common box type
    product description08
    product description09
    product description10
    product description11

    Frequently Asked Questions (FAQ)

    Q1: What are the main application environments for this switchgear?

    A: The switchgear is highly suitable for secondary small distribution substations, industrial and mining enterprises, airports, railways, commercial districts, high-rise buildings, highways, subways, tunnels, and other locations with severe or harsh environmental conditions.

    Q2: Why is this switchgear considered green and environment-friendly?

    A: Unlike traditional systems, it uses nitrogen or dry air insulation instead of SF6 gas, resulting in zero greenhouse gas emissions. Additionally, raw materials are strictly controlled, and the recycle rate of materials can reach up to 90% after retirement.

    Q3: How does the sealed design protect the switchgear?

    A: The primary live parts and the switch itself are sealed inside a welded stainless steel gas tank with an IP67 protection grade. This fully insulated design isolates the internal components from external environmental factors and provides short-term resistance to flood and condensation.

    Q4: What is the mechanical life of the switches used in this equipment?

    A: The circuit breaker (CB) and load switch units are designed for a mechanical life of 10,000 operations, while the three-position switch is rated for 5,000 operations.

    Q5: What safety interlocks are integrated into the operation design?

    A: The switchgear features comprehensive mechanical interlocks. For example, the cable compartment front door can only be opened when the earthing switch is closed and the circuit breaker/load switch is open. Similarly, the isolation and earthing switches cannot be operated when the circuit breaker is in the closed position.

    Q6: What are the standard service conditions for temperature and altitude?

    A: The standard ambient temperature range is -45℃ to +50℃ (daily average ≤ 35℃), and the standard altitude limit is up to 4000m. For operations above 1000m, adjustments to the inflation pressure should be noted prior to installation.