General 
The GTD9-12D indoor high voltage AC isolating switch is a premium product designed for reliable performance in high voltage applications. Manufactured in China, this isolating switch features an insulation distance and clear disconnection marks between the contacts that comply with all specified safety requirements when in the open position. In the closed position, it efficiently carries current under normal circuit conditions as well as managing abnormal conditions, such as short circuits, within a designated timeframe. This robust switch is capable of handling the opening and closing of no-load currents, including inductive or capacitive small currents. As a reputable factory among top suppliers, we prioritize quality and safety in all our high voltage solutions.

    Detail introduction
    This product is suitable for three-phase AC 50/60HZ, 12KV no-load current situations. When isolation, maintenance or repair of the circuit is required, the circuit can be disconnected or closed to achieve safe isolation and ensure the safety of operators and equipment. The layout, appearance, and dimensions of this isolating switch are completely consistent with VTD9-12D and FTD9-12D vacuum switches. It is a typical through wall isolating switch that is easy to expand and combine in switchgear.
    IEC62271-1 High voltage switchgear and control equipment - Part 1: Common technical requirements for AC switchgear and control equipment
    IEC62271-102 High voltage switchgear and control equipment - Part 102: AC isolating switches and grounding switches
    GB/T1985 High voltage AC isolating switch and grounding switch
    GB/T11022 Common Technical Requirements for High Voltage Switchgear and Control Equipment Standards
    DL/T486 High voltage AC isolating switch and grounding switch
    Service Conditions
    Environmental temperature: -25℃ ~ +40℃
    Altitude: ≤ 1000m
    Relative humidity:
    Daily average relative humidity ≤ 95%
    Monthly average relative humidity ≤ 90%
    Daily average vapor pressure ≤ 2.2x10-3 MPa
    Monthly average vapor pressure ≤ 1.8x10-3 MPa
    Seismic grade: seismic intensity ≤ 8
    Applicable location: Free from dripping water, flammable and explosive hazards, chemical corrosive gases, and severe vibrations.
    ※ Note: When the usage environment deviates from normal usage conditions, please consult with our company to determine.
    Technical Data
    Item Unit Parameter
    Rated frequency Hz 50/60
    Rated voltage kV 12
    Rated power frequency withstand voltage (1 minute, r.m.s) Phase to phase and phase to ground KV 42
    Isolation fracture 48
    Control and auxiliary circuits 2
    Rated lightning impulse withstand voltage (peak) Phase to phase and phase to ground kV 75
    Isolation fracture 85
    Rated current A 630, 1250
    Rated short-circuit breaking current (r.m.s) kA /
    Rated short-time withstand current and time kA/s 20/4, 25/4, 31.5/4
    Rated peak withstand current kA 50, 63, 80
    Rated short-circuit making current (peak) kA /
    Rated breaking current of single/back-to-back capacitor group A /
    Rated capacitor bank making current kA /
    Rated handover (transfer) current A /
    Mechanical life Times 3000
    Main circuit resistance of each phase ≤ 45, ≤ 40
    Clearance between open contacts mm 125 ± 1
    Contacting travel mm /
    Contact closing bounce time mm /
    Three-phase asynchronous closing and opening ms /
    Average opening speed (contact just opened - 6mm) m/s /
    Average closing speed ( 6mm - contact just opened) m/s /
    Rated contact pressure N /
    Opening time (at rated voltage) ms /
    Closing time (at rated voltage) ms /
    Rated operating sequence /
    Typical outline dimensions (fit) and structural diagram
    product description01
    Rated current (A) 630 1250
    Rated short-time withstand current (kA, 4s) 25
    Inter-phase distance (mm) 210
    GTD9-12 (inter-phase distance P=210) outline dimension drawing of isolating switch (This diagram shows the product in the upright position, and the product can also be installed in an inverted position.)
    product description02
    Rated current (A) 630 1250
    Rated short-time withstand current (kA, 4s) 25
    Inter phase distance (mm) 210
    GTD9-12D (inter-phase distance P=210) outline dimension drawing of isolating switch (This diagram shows the product in the upright position, and the product can also be installed in an inverted position.)
    Frequently Asked Questions
    What electrical systems is this isolating switch suitable for?
    This isolating switch is suitable for three-phase AC 50/60Hz systems with a 12KV no-load current situation.
    What are the key standard requirements complied with?
    The product complies with international and national standards including IEC62271-1, IEC62271-102, GB/T1985, GB/T11022, and DL/T486.
    What are the normal environmental temperature limits for operation?
    The normal environmental temperature range for the service conditions is -25℃ to +40℃.
    Can this isolating switch be mounted in different directions?
    Yes. While diagrams show the product in the upright position, it can also be installed in an inverted position.
    What is the mechanical life rating of this switch?
    The mechanical life of this isolating switch is rated for 3000 operation times.

    Leave Your Message