General 
The KYN61-40.5 withdrawable metal-clad switchgear, known as KYN61 switchgear, is a reliable and cost-effective solution for high-voltage applications. Designed for 40.5kV three-phase AC systems, this switchgear features a single busbar and a single sectional system, making it an ideal choice for various industries.

,

 

,

This versatile switchgear can be utilized in power distribution for substations, transmission and transformation systems, wind farms, iron and steel works, as well as in the petroleum and chemical industries, mining operations, and food and paper production. It provides essential control, protection, and monitoring functions. As a leading product from trusted China suppliers and manufacturers, the KYN61 switchgear ensures high performance and quality for your electrical systems.

    Detail introduction

    In the KYN61-40.5 withdrawable AC metal-clad switchgear, the handcart is equipped with an integrated ZN85 (VTD9) ND4-40.5 vacuum circuit breaker or a corresponding SF6 circuit breaker as the main switch. The design is compact, with superior performance and high reliability.
    KYN61 switchgear comply with the standards: IEC62271-200, GB3906 as well as many other national specifications, with reliable "five-protection interlock" function, providing a safer environment for the operators, with high structure strength, safe and user-friendly, reduced installation and maintenance costs, can completely satisfy user requirements.

    Service Conditions

    • a Ambient temperature: -15℃~+40℃
    • b Altitude: ≤1000M
    • c Relative humidity: Daily average relative humidity ≤95%, Monthly average relative humidity ≤90%
    • d Seismic resistant level: < Grade 8
    • e Ambient air should be free of the pollution of corrosive or flammable gases, vapor, etc.
    ※Note: If the service environment exceeds the above conditions, please confirm with the manufacturer.

    Technical Data

    Main technical data of KYN61 switchgear
    Item Unit Technical parameters
    Rated voltage kV 40.5
    Rated frequency Hz 50/60
    Rated current of branch busbar A 630、1250、1600、2000、2500、3150
    Rated insulation level Power frequency withstand voltage (1 min) kV 95/118(isolating fracture)
    Lightning impulse withstand voltage 185/215(isolating fracture)
    Power frequency withstand voltage of auxiliary circuit (1 min) V 2000
    Rated short circuit breaking current (rms) kA 25、31.5
    Rated short time making current (peak) kA 63、80
    Rated short time peak withstand current kA 63、80
    Rated short time withstand current (4s) kA 25、31.5
    Rated voltage of auxiliary control circuit V DC110/220 AC220
    Protection degree - External enclosure: IP4X (the panel open: IP2X)
    External dimensions of switchgear (W x D x H) mm 1400×2800×2600 / 1200×2600×2400(optional)

    Structure features

    KYN61 switchgear is designed as per the standard of metal-clad switchgear, conforms to IEC 62271 and GB/T3906. It mainly includes panel structure and the withdrawable part. The panel itself consists of four independent compartments: busbar compartment, circuit breaker compartment, cable compartment, low voltage compartment. The protection degree of enclosure is IP4X, and IP2X for compartments. The withdrawable part includes the main switch (or other functional components) and support part. (The structure is shown in drawing 1)
    KYN61 switchgear provides bottom and overhead incoming and outgoing cable types, typical scheme including incomer, feeder, metering, measuring coupler, etc.
    product description01
    Drawing 1: Outline dimension and structure of switchgear
    Compartments
    A. Instrument room
    B. Circuit breaker room
    C. Busbar room
    D. Cable room
    Components
    1. Panel    2. Circuit breaker    3. Contact box
    4. Secondary plug device    5. Valve
    6. Pressure relief device    7. Small busbar
    8. Busbar bushing    9. Main busbar
    10. Branch busbar    11. Fixed contact
    12. Insulated clapboard    13. Earthing switch
    14. Current transformer    15. Cable
    16. Cable cover plate    17. Earthing busbar

    Order Notes

    The clients should provide the following documents:
    • a Main wiring scheme No., single line system diagram, arrangement diagram and layout plan.
    • b The requirements for control, measurement and protection of switchgears, and requirements for other interlocks and automatic devices.
    • c Main components type, specification and quantity in switchgear.
    • d If need busbar bridge, please provide the size of span and height.
    • e If the switchgear used under special condition, please inform the details.
    • f Please provide type and quantity if need additional parts.

    Frequently Asked Questions (FAQ)

    What standards does the KYN61 switchgear comply with?

    The KYN61 switchgear complies with international and national standards including IEC62271-200 and GB3906, ensuring high structural strength, reliable performance, and safety.

    What main switches can be installed in the handcart?

    The handcart is equipped with an integrated ZN85 (VTD9) ND4-40.5 vacuum circuit breaker or a corresponding SF6 circuit breaker as the main switch.

    What are the normal environmental service conditions for this switchgear?

    Standard conditions include an ambient temperature of -15℃ to +40℃, altitude ≤1000m, daily average relative humidity ≤95% (monthly ≤90%), seismic resistance below Grade 8, and air free of corrosive or flammable gases.

    What is the protection degree of the KYN61 switchgear?

    The external enclosure protection degree is IP4X. When the panel is open, the internal compartments feature a protection degree of IP2X.

    What are the main independent compartments inside the switchgear?

    The switchgear panel consists of four independent compartments: the busbar compartment, the circuit breaker compartment, the cable compartment, and the low voltage compartment.

    What information should be provided when placing an order?

    Clients must provide the main wiring scheme, control/protection requirements, component specifications and quantities, busbar bridge dimensions (if needed), special environmental conditions, and requirements for additional parts.