Leave Your Message

KYN61-40.5 Air-Insulated Withdrawable Metal-Clad Switchgear - Reliable China Suppliers and Factory Solutions

General 
The KYN61-40.5 withdrawable metal-clad switchgear, known as KYN61 switchgear, is a cost-effective and reliable solution designed to meet the demands of modern electrical systems. Manufactured by leading China suppliers, this switchgear operates at a voltage of 40.5kV and features a three-phase AC single busbar and single sectional system.

,

 

,

This versatile switchgear is ideal for use in power distribution within substations, as well as in transmission and transformation systems. It is equally suitable for various industries such as wind farms, iron and steel production, the petroleum and chemical industries, mining enterprises, and the paper and food industries. The KYN61 switchgear provides essential functions for control, protection, and monitoring, making it an indispensable choice for any electrical setup. Get your KYN61 switchgear from a reputable China factory today!

    Detail introduction

    In the KYN61-40.5 withdrawable AC metal-clad switchgear, the handcart is equipped with an integrated ZN85 (VTD9) ND4-40.5 vacuum circuit breaker or a corresponding SF6 circuit breaker as the main switch. The design is compact, with superior performance and high reliability.
    KYN61 switchgear comply with the standards: IEC62271-200, GB3906 as well as many other national specifications, with reliable "five-protection interlock" function, providing a safer environment for the operators,with high structure strength, safe and user-friendly, reduced installation and maintenance costs, can completely satisfy user requirements.

    Service Conditions

    Temperature & Altitude
    Ambient temperature: -15℃~+40℃
    Altitude: ≤1000M
    Humidity & Seismic
    Daily average RH: ≤95%
    Monthly average RH: ≤90%
    Seismic resistant level: < Grade 8
    Environment
    Ambient air should be free of the pollution of corrosive or flammable gases, vapor, etc.
    ※Note: If the service environment exceeds the above conditions, please confirm with the manufacturer.

    Technical Data

    Main technical data of KYN61 switchgear
    Item Unit Technical parameters
    Rated voltage kV 40.5
    Rated frequency Hz 50/60
    Rated current of branch busbar A 630、1250、1600、2000、2500、3150
    Rated insulation level Power frequency withstand voltage (1 min) kV 95/118 (isolating fracture)
    Lightning impulse withstand voltage 185/215 (isolating fracture)
    Power frequency withstand voltage of auxiliary circuit (1 min) V 2000
    Rated short circuit breaking current (rms) kA 25、31.5
    Rated short time making current (peak) kA 63、80
    Rated short time peak withstand current kA 63、80
    Rated short time withstand current (4s) kA 25、31.5
    Rated voltage of auxiliary control circuit V DC110/220 AC220
    Protection degree - External enclosure: IP4X (the panel open: IP2X)
    External dimensions of switchgear (W x D x H) mm 1400×2800×2600   1200×2600×2400 (optional)

    Structure features

    KYN61 switchgear is designed as per the standard of metal-clad switchgear, conforms to IEC 62271 and GB/T3906. It mainly includes panel structure and the withdrawable part. The panel itself consists of four independent compartments: busbar compartment, circuit breaker compartment, cable compartment, low voltage compartment. The protection degree of enclosure is IP4X, and P2X for compartments. The withdrawable part includes the main switch (or other functional components)and support part. (The structure is shown in drawing 1)
    KYN61 switchgear provides bottom and overhead incoming and outgoing cable types, typical scheme including incomer, feeder, metering, measuring coupler, etc.
    product description01
    Drawing 1: Outline dimension and structure of switchgear
    Main Compartments
    A. Instrument room
    B. Circuit breaker room
    C. Busbar room
    D. Cable room
    Components & Parts
    1. Panel
    2. Circuit breaker
    3. Contact box
    4. Secondary plug device
    5. Valve
    6. Pressure relief device
    7. Small busbar
    8. Busbar bushing
    9. Main busbar
    10. Branch busbar
    11. Fixed contact
    12. Insulated clapboard
    13. Earthing switch
    14. Current transformer
    15. Cable
    16. Cable cover plate
    17. Earthing busbar

    Order Notes

    The clients should provide the following documents:
    • Main wiring scheme No., single line system diagram, arrangement diagram and layout plan.
    • The requirements for control, measurement and protection of switchgears, and requirements for other interlocks and automatic devices.
    • Main components type, specification and quantity in switchgear.
    • If need busbar bridge, please provide the size of span and height.
    • If the switchgear used under special condition, please inform the details.
    • Please provide type and quantity if need additional parts.
    Frequently Asked Questions
    Q What standards does the KYN61-40.5 switchgear comply with?
    KYN61 switchgear complies fully with IEC62271-200 and GB3906 standards, along with various other national specifications. It features a highly reliable "five-protection interlock" function to ensure operator safety.
    Q What are the standard ambient service conditions for this switchgear?
    The standard operating conditions include an ambient temperature range of -15℃ to +40℃, an altitude of ≤1000 meters, daily average relative humidity ≤95%, monthly average relative humidity ≤90%, and a seismic resistance level under Grade 8 in an environment free of corrosive or flammable gases.
    Q What type of circuit breakers can be used in the handcart?
    The handcart is equipped with an integrated ZN85 (VTD9) ND4-40.5 vacuum circuit breaker or a corresponding SF6 circuit breaker as the main switch, designed for compact layout and high reliability.
    Q What is the protection degree of the KYN61 switchgear?
    The external enclosure provides a protection degree of IP4X. When the panel is open, the internal compartments have a protection rating of IP2X.
    Q What information is required when placing an order?
    Clients need to provide the main wiring scheme, single line diagram, control and protection requirements, specifications and quantities of main components, busbar bridge dimensions (if required), special environmental conditions (if any), and the type and quantity of any additional spare parts.

    Leave Your Message