TANW1 Series Intelligent Universal LV Circuit Breaker - Reliable Protection from China Suppliers and Factory
General
The TANW1 series intelligent universal low voltage circuit breaker (hereinafter referred to as the circuit breaker) is suitable for distribution networks with AC 50/60Hz, rated voltages of 400V, 690V, and rated currents of 630A~6300A (four pole suitable for three-phase four wire or three-phase five wire systems), used to distribute electrical energy and protect lines and power equipment from overload, under-voltage, short circuit, single-phase grounding and other faults. Circuit breakers have intelligent protection functions, precise selective protection, can improve power supply reliability and avoid unnecessary power outages. It can be equipped with an open communication interface for four remote control to meet the requirements of the distribution automation system. This circuit breaker is not equipped with an intelligent controller or CT & PT, and can be used as an isolator, marked as
.
Standards
The circuit breaker complies with standards such as IEC60947-2 and GB14048.2 "Low voltage switchgear and control equipment - Low voltage circuit breakers".
Type and Designation
Classification
Service Condition
Technical data and performance
| Shell level rated current Inm (A) | Rated current In (A) |
|---|---|
| 2000 | 630, 800, 1000, 1250, 1600, 2000 |
| 3200 | 2000, 2500, 2900, 3200 |
| 4000 | 3200, 3600, 4000 |
| 6300 | 4000, 5000, 6300 |
| Shell level rated current Inm (A) | 400V (kA) | 690V (kA) | ||||
|---|---|---|---|---|---|---|
| Rated ultimate short-circuit breaking capacity Icu | Rated operating short-circuit breaking capacity Ics | Rated short-time withstand current Icw1s with a delay of 0.4s, O-CO | Rated ultimate short-circuit breaking capacity Icu | Rated operating short-circuit breaking capacity Ics | Rated short-time withstand current Icw1s with a delay of 0.4s, O-CO | |
| 2000 | 80 | 50 | 50 | 50 | 40 | 40 |
| 3200 | 100 | 80 | 80 | 65 | 65 | 50 |
| 4000 | 100 | 80 | 65/75(MCR) | 75 | 65 | 50/65(MCR) |
| 6300 | 100 | 100 | 85/100(MCR) | 85 | 75 | 65/75(MCR) |
| Ambient temperature | +40℃ | +45℃ | +50℃ | +55℃ | +60℃ | |
|---|---|---|---|---|---|---|
| Allow continuous operating current | 2000A | 1In | 0.95In | 0.9Ln | 0.85In | 0.8In |
| 3200A | 1In | 0.92In | 0.86In | 0.80In | 0.74In | |
| 4000A | 1In | 0.93In | 0.87In | 0.81In | 0.75In | |
| 5000A | 1In | 0.94In | 0.88In | 0.82In | 0.76In | |
| Note: Relationship between ambient air temperature and allowable continuous operating current (based on the measured temperature at the inlet and outlet of the circuit breaker reaching 110 ℃ under various environmental temperature conditions) | ||||||
| Altitude(m) | 2000 | 3000 | 4000 | 5000 |
|---|---|---|---|---|
| Power-frequency withstand voltage(V) | 3500 | 3150 | 2500 | 2000 |
| Correction coefficient for working current | 1 | 0.93 | 0.88 | 0.82 |
| Correction factor for short-circuit breaking capacity | 1 | 0.83 | 0.71 | 0.63 |
The operational performance of a circuit breaker is represented by the number of operating cycles
| Shell level rated current (A) | No. of power on operation cycles | No. of non powered operation cycles | Total |
|---|---|---|---|
| 2000 | 500 | 4500 | 5000 |
| 3200、4000 | 500 | 2500 | 3000 |
| 6300 | 500 | 1500 | 2000 |
Appearance and installation dimensions









A1: It is designed for distribution networks with AC 50/60Hz, rated voltages of 400V/690V, and rated currents of 630A~6300A. It distributes electrical energy and protects lines and power equipment against overload, under-voltage, short circuits, and single-phase grounding faults.
A2: The circuit breaker complies with international standards such as IEC60947-2 and national standards like GB14048.2 (Low voltage switchgear and control equipment - Low voltage circuit breakers).
A3: Yes. When the circuit breaker is not configured with an intelligent controller or CT & PT, it can be used as an isolator.
A4: The ambient air temperature should be within -5 ℃ to +40 ℃, with a 24-hour average temperature not exceeding +35 ℃. For temperatures outside this range (below -10 ℃ or above +40 ℃), users should consult the manufacturer.
A5: For altitudes exceeding 2000m, electrical performance parameters must be corrected. For example, at 5000m, the power-frequency withstand voltage reduces to 2000V, the working current correction factor is 0.82, and the short-circuit breaking capacity factor is 0.63.
A6: In terms of installation, it is available in Fixed type and Withdrawable type. For operation, it supports Electric operation and Manual operation (mainly used for maintenance and repair).